2016•Science and Technology for the Built EnvironmentRequires access

Performance investigation and exergy analysis of air-handling processes using liquid desiccant and a desiccant wheel

Tao Zhang, Xiaohua Liu, Jùn Líu

Open publisher page 8 citations

Abstract

Air-dehumidification systems using liquid desiccant and a desiccant wheel are common approaches using desiccant for air humidity control. This article focuses on the performance of air-dehumidification systems using liquid desiccant and a desiccant wheel. Based on basic air-handling processes using desiccants, the characteristics of the driving forces are investigated with the help of an unmatched coefficient ξ and exergy analysis. The performace of liquid desiccant and desiccant wheel systems is investigated, and approaches for improvement are proposed. It is indicated that the temperature difference ΔT or humidity ratio difference Δω in the liquid desiccant process is influenced by the inlet state of the air and solution. The liquid desiccant process heating solution, rather than air, for regeneration is optimal from the perspective of lowering ξ and reducing unmatched destruction. The ξ is approaching 1 between air and solid desiccant, i.e., the driving force is relatively uniform with the same dehumidification and regeneration regions. A multi-stage process is supposed to be effective for optimizing the desiccant wheel system, helping to reduce the exergy destruction arising from the unmatched coefficient. The present study is beneficial to cast light on the relationship between air-dehumidification systems using liquid desiccant and a desiccant wheel.

About this research paper

What this paper is about

Air-dehumidification systems using liquid desiccant and a desiccant wheel are common approaches using desiccant for air humidity control. This article focuses on the performance of air-dehumidification systems using liquid desiccant and a desiccant wheel. Based on basic air-handling processes using desiccants, the characteristics of the driving forces are investigated with the help of an unmatched coefficient ξ and exergy analysis. The performace of liquid desiccant and desiccant wheel systems is investigated, and approaches for improvement are proposed. It is indicated that the temperature difference ΔT or humidity ratio difference Δω in the liquid desiccant process is influenced by the inlet state of the air and solution. The liquid desiccant process heating solution, rather than air, for regeneration is optimal from the perspective of lowering ξ and reducing unmatched destruction. The ξ is approaching 1 between air and solid desiccant, i.e., the driving force is relatively uniform with the same dehumidification and regeneration regions. A multi-stage process is supposed to be effective for optimizing the desiccant wheel system, helping to reduce the exergy destruction arising from the unmatched coefficient. The present study is beneficial to cast light on the relationship between air-dehumidification systems using liquid desiccant and a desiccant wheel.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Air-dehumidification systems using liquid desiccant and a desiccant wheel are common approaches using desiccant for air humidity control. This article focuses on the performance of air-dehumidification systems using liquid desiccant and a desiccant wheel. Based on basic air-handling processes using desiccants, the characteristics of the driving forces are investigated with the help of an unmatched coefficient ξ and exergy analysis. The performace of liquid desiccant and desiccant wheel systems is investigated, and approaches for improvement are proposed. It is indicated that the temperature difference ΔT or humidity ratio difference Δω in the liquid desiccant process is influenced by the inlet state of the air and solution. The liquid desiccant process heating solution, rather than air, for regeneration is optimal from the perspective of lowering ξ and reducing unmatched destruction. The ξ is approaching 1 between air and solid desiccant, i.e., the driving force is relatively uniform with the same dehumidification and regeneration regions. A multi-stage process is supposed to be effective for optimizing the desiccant wheel system, helping to reduce the exergy destruction arising from the unmatched coefficient. The present study is beneficial to cast light on the relationship between air-dehumidification systems using liquid desiccant and a desiccant wheel.

Key concepts: Desiccant, Liquid desiccant, Exergy, Humidity, Process (computing), Environmental science, Exergy efficiency, Process engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance investigation and exergy analysis of air-handling processes using liquid desiccant and a desiccant wheel — Research Paper | ScholarLens