2000IEEJ Transactions on Electronics Information and SystemsOpen access

Total Power Radiometer for Microwave Noise Measurement

Hiroshi Nakano, Takemi Inoue, Y. Kato

Open full text 8 citations

Abstract

Two types of radiometers are generally used for microwave noise measurements. One is a total power type and the other is the Dicke type. The former is theoretically the most sensitive and more broadband in frequency, but it is slightly unstable and worse in the linearity of the receiver gain. From the viewpoint of realizing a broadband radiometer, the total power type has been adopted for precision noise measurements. In order to reduce the influence of non-linearity, a differential detection scheme has been employed in the detection section. And also in order to reduce the instability of the gain, the temperature of the front end section and the IF and detection section has been stabilized with circulated warmed water. Based on these ideas, a new microwave radiometer has been built. In addition a new equation of the output indication for the total power radiometer has been derived. By using this equation, an equation has been derived for making noise calibration and several equations have been derived for measuring parameters indicating the characteristics of the radiometer, which are important to perform precision noise measurements. And the effectiveness of the radiometer has been proven experimentally using these equations.

Open-access reader

About this research paper

What this paper is about

Two types of radiometers are generally used for microwave noise measurements. One is a total power type and the other is the Dicke type. The former is theoretically the most sensitive and more broadband in frequency, but it is slightly unstable and worse in the linearity of the receiver gain. From the viewpoint of realizing a broadband radiometer, the total power type has been adopted for precision noise measurements. In order to reduce the influence of non-linearity, a differential detection scheme has been employed in the detection section. And also in order to reduce the instability of the gain, the temperature of the front end section and the IF and detection section has been stabilized with circulated warmed water. Based on these ideas, a new microwave radiometer has been built. In addition a new equation of the output indication for the total power radiometer has been derived. By using this equation, an equation has been derived for making noise calibration and several equations have been derived for measuring parameters indicating the characteristics of the radiometer, which are important to perform precision noise measurements. And the effectiveness of the radiometer has been proven experimentally using these equations.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two types of radiometers are generally used for microwave noise measurements. One is a total power type and the other is the Dicke type. The former is theoretically the most sensitive and more broadband in frequency, but it is slightly unstable and worse in the linearity of the receiver gain. From the viewpoint of realizing a broadband radiometer, the total power type has been adopted for precision noise measurements. In order to reduce the influence of non-linearity, a differential detection scheme has been employed in the detection section. And also in order to reduce the instability of the gain, the temperature of the front end section and the IF and detection section has been stabilized with circulated warmed water. Based on these ideas, a new microwave radiometer has been built. In addition a new equation of the output indication for the total power radiometer has been derived. By using this equation, an equation has been derived for making noise calibration and several equations have been derived for measuring parameters indicating the characteristics of the radiometer, which are important to perform precision noise measurements. And the effectiveness of the radiometer has been proven experimentally using these equations.

Key concepts: Radiometer, Microwave radiometer, Linearity, Noise (video), Broadband, Microwave, Noise temperature, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Total Power Radiometer for Microwave Noise Measurement — Research Paper | ScholarLens