2016Journal of the Korean Society of RadiologyOpen access

The Study on Reduction of Image Distortion by using Single-Shot Turbo Spin Echo in Brain Stem Diffusion MRI

Kwan-Woo Choi, Ho-Beom Lee, Sa-Ra Na, Beong-Gyu Yoo, Soon-Yong Son

Open full text 1 citations

Abstract

본 연구는 DWI 검사 시 자화율 차이로 인해 뇌줄기에 발생하는 영상의 왜곡을 새로운 SS-TSE를 적용하여 감소시키고자 하였다. 연구방법은 2015년 7월부터 동년 9월까지 DWI 검사를 검사한 30명을 대상으로, 기존의 SS-EPI 기법과 새로운 SS-TSE를 적용하여 기법에 따른 뇌줄기의 왜곡과 오차율을 비교평가 하였다. 연구결과, 새로운 SS-TSE 적용 시 왜곡이 감소된 것을 볼 수 있으며, 오차율 또한 b0 영상은 2.4%(11.1%에서 8.7%), b1000 영상은 1.2%(11.4%에서 10.1%) 감소하는 것을 볼 수 있었다. 결론적으로, 뇌줄기의 DWI 검사 시 본 연구의 SS-TSE를 이용하면 기존 기법 사용 시 발생하는 영상의 왜곡을 감소시킬 수 있어 진단적 가치가 높은 영상을 획득할 수 있다. Single-shot echo planar imaging(SS-EPI) is well established as high sensitivity for ischemic stroke. However, it is prone to susceptibility artifact in brain stem that diminish the image quality. single-shot turbo spin echo(SS-TSE) is a new DWI technique that can reduce susceptibility artifact. Thus, this research was conducted so as to reduce geometric distortion in brain stem by using single-shot turbo spin echo technique. Thirty patients without brain disease underwent diffusion MR on a 3T scanner with SS-EPI and SS-TSE. Obtained images with both sequences were analyzed for geometric distortion and error percentage as well. Image quality in terms of geometric distortion of SS-TSE were found to be significantly better than those for SS-EPI. And error percentage was considerably reduced for 2.4% of b0 image(from 11.1% to 8.7%), 1.2% of b1000 image(from 11.4% to 10.1%), respectively. In summary, diffusion MR using SS-TSE significantly reduce geometric distortion compared to SS-EPI in brain stem and may provide improved diagnostic performance.

Open-access reader

About this research paper

What this paper is about

본 연구는 DWI 검사 시 자화율 차이로 인해 뇌줄기에 발생하는 영상의 왜곡을 새로운 SS-TSE를 적용하여 감소시키고자 하였다. 연구방법은 2015년 7월부터 동년 9월까지 DWI 검사를 검사한 30명을 대상으로, 기존의 SS-EPI 기법과 새로운 SS-TSE를 적용하여 기법에 따른 뇌줄기의 왜곡과 오차율을 비교평가 하였다. 연구결과, 새로운 SS-TSE 적용 시 왜곡이 감소된 것을 볼 수 있으며, 오차율 또한 b0 영상은 2.4%(11.1%에서 8.7%), b1000 영상은 1.2%(11.4%에서 10.1%) 감소하는 것을 볼 수 있었다. 결론적으로, 뇌줄기의 DWI 검사 시 본 연구의 SS-TSE를 이용하면 기존 기법 사용 시 발생하는 영상의 왜곡을 감소시킬 수 있어 진단적 가치가 높은 영상을 획득할 수 있다. Single-shot echo planar imaging(SS-EPI) is well established as high sensitivity for ischemic stroke. However, it is prone to susceptibility artifact in brain stem that diminish the image quality. single-shot turbo spin echo(SS-TSE) is a new DWI technique that can reduce susceptibility artifact. Thus, this research was conducted so as to reduce geometric distortion in brain stem by using single-shot turbo spin echo technique. Thirty patients without brain disease underwent diffusion MR on a 3T scanner with SS-EPI and SS-TSE. Obtained images with both sequences were analyzed for geometric distortion and error percentage as well. Image quality in terms of geometric distortion of SS-TSE were found to be significantly better than those for SS-EPI. And error percentage was considerably reduced for 2.4% of b0 image(from 11.1% to 8.7%), 1.2% of b1000 image(from 11.4% to 10.1%), respectively. In summary, diffusion MR using SS-TSE significantly reduce geometric distortion compared to SS-EPI in brain stem and may provide improved diagnostic performance.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

본 연구는 DWI 검사 시 자화율 차이로 인해 뇌줄기에 발생하는 영상의 왜곡을 새로운 SS-TSE를 적용하여 감소시키고자 하였다. 연구방법은 2015년 7월부터 동년 9월까지 DWI 검사를 검사한 30명을 대상으로, 기존의 SS-EPI 기법과 새로운 SS-TSE를 적용하여 기법에 따른 뇌줄기의 왜곡과 오차율을 비교평가 하였다. 연구결과, 새로운 SS-TSE 적용 시 왜곡이 감소된 것을 볼 수 있으며, 오차율 또한 b0 영상은 2.4%(11.1%에서 8.7%), b1000 영상은 1.2%(11.4%에서 10.1%) 감소하는 것을 볼 수 있었다. 결론적으로, 뇌줄기의 DWI 검사 시 본 연구의 SS-TSE를 이용하면 기존 기법 사용 시 발생하는 영상의 왜곡을 감소시킬 수 있어 진단적 가치가 높은 영상을 획득할 수 있다. Single-shot echo planar imaging(SS-EPI) is well established as high sensitivity for ischemic stroke. However, it is prone to susceptibility artifact in brain stem that diminish the image quality. single-shot turbo spin echo(SS-TSE) is a new DWI technique that can reduce susceptibility artifact. Thus, this research was conducted so as to reduce geometric distortion in brain stem by using single-shot turbo spin echo technique. Thirty patients without brain disease underwent diffusion MR on a 3T scanner with SS-EPI and SS-TSE. Obtained images with both sequences were analyzed for geometric distortion and error percentage as well. Image quality in terms of geometric distortion of SS-TSE were found to be significantly better than those for SS-EPI. And error percentage was considerably reduced for 2.4% of b0 image(from 11.1% to 8.7%), 1.2% of b1000 image(from 11.4% to 10.1%), respectively. In summary, diffusion MR using SS-TSE significantly reduce geometric distortion compared to SS-EPI in brain stem and may provide improved diagnostic performance.

Key concepts: Fast spin echo, Single shot, Artifact (error), Distortion (music), Image quality, Nuclear medicine, Diffusion MRI, Echo-planar imaging

Related papers

Back to paper searchBrowse research topicsOriginal source
The Study on Reduction of Image Distortion by using Single-Shot Turbo Spin Echo in Brain Stem Diffusion MRI — Research Paper | ScholarLens