2016•Asian Spine JournalOpen access

Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws

Michael Siu Hei Tse, Chi Hin Chan, Kam Kwong Wong, Wing Cheung Wong

Open full text 14 citations

Abstract

STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.

Open-access reader

About this research paper

What this paper is about

STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

STUDY DESIGN: Retrospective study. PURPOSE: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.

Key concepts: Lateral mass, Medicine, Vertebra, Cervical vertebrae, Anatomy, Fixation (population genetics), Cervical spine, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws — Research Paper | ScholarLens