2016Asian Journal of Pharmaceutical ResearchRequires access

Simultaneous UV Spectrophotometric Methods for Estimation of Cefixime Trihydrate and Ofloxacin in Bulk and Tablet Dosage Form

Audumbar Mali, Santosh A. Jadhav, Rahul Gorad, Aamer Quazi, Ritesh Suresh Bathe, Manojkumar Patil, Ashpak Tamboli

Open publisher page 8 citations

Abstract

Simple, precise, economical, fast and reliable two UV methods have been developed for the simultaneous estimation of Cefixime Trihydrate and Ofloxacin in bulk and pharmaceutical dosage form. Method A is Absorbance maxima method, which is based on measurement of absorption at maximum wavelength of 287 nm and 296 nm for Cefixime Trihydrate and Ofloxacin respectively. Method B is area under curve (AUC), in the wavelength range of 265–301 nm for Cefixime Trihydrate and277-320nm for Ofloxacin. Linearity for detector response was observed in the concentration range of 5–25μg/ml for Cefixime Trihydrate and 5–25 μg/ml for Ofloxacin. The accuracy of the methods was assessed by recovery studies and was found to be 98.83% and 100.12% for Cefixime Trihydrate and 102.71% and 99.01% Ofloxacin by using method A and B respectively. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically as per ICH Q2 R1guideline and were found to be satisfactory. The proposed methods were successfully applied for the determination of for Cefixime Trihydrate and Ofloxacin in commercial pharmaceutical dosage form.

About this research paper

What this paper is about

Simple, precise, economical, fast and reliable two UV methods have been developed for the simultaneous estimation of Cefixime Trihydrate and Ofloxacin in bulk and pharmaceutical dosage form. Method A is Absorbance maxima method, which is based on measurement of absorption at maximum wavelength of 287 nm and 296 nm for Cefixime Trihydrate and Ofloxacin respectively. Method B is area under curve (AUC), in the wavelength range of 265–301 nm for Cefixime Trihydrate and277-320nm for Ofloxacin. Linearity for detector response was observed in the concentration range of 5–25μg/ml for Cefixime Trihydrate and 5–25 μg/ml for Ofloxacin. The accuracy of the methods was assessed by recovery studies and was found to be 98.83% and 100.12% for Cefixime Trihydrate and 102.71% and 99.01% Ofloxacin by using method A and B respectively. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically as per ICH Q2 R1guideline and were found to be satisfactory. The proposed methods were successfully applied for the determination of for Cefixime Trihydrate and Ofloxacin in commercial pharmaceutical dosage form.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Simple, precise, economical, fast and reliable two UV methods have been developed for the simultaneous estimation of Cefixime Trihydrate and Ofloxacin in bulk and pharmaceutical dosage form. Method A is Absorbance maxima method, which is based on measurement of absorption at maximum wavelength of 287 nm and 296 nm for Cefixime Trihydrate and Ofloxacin respectively. Method B is area under curve (AUC), in the wavelength range of 265–301 nm for Cefixime Trihydrate and277-320nm for Ofloxacin. Linearity for detector response was observed in the concentration range of 5–25μg/ml for Cefixime Trihydrate and 5–25 μg/ml for Ofloxacin. The accuracy of the methods was assessed by recovery studies and was found to be 98.83% and 100.12% for Cefixime Trihydrate and 102.71% and 99.01% Ofloxacin by using method A and B respectively. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically as per ICH Q2 R1guideline and were found to be satisfactory. The proposed methods were successfully applied for the determination of for Cefixime Trihydrate and Ofloxacin in commercial pharmaceutical dosage form.

Key concepts: Cefixime, Ofloxacin, Dosage form, Chromatography, Cephalosporin, Mathematics, Medicine, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous UV Spectrophotometric Methods for Estimation of Cefixime Trihydrate and Ofloxacin in Bulk and Tablet Dosage Form — Research Paper | ScholarLens