2003•International Journal of VentilationRequires access

Room Air Distribution and Indoor Air Quality of Hybrid Air Conditioning System based on Natural and Mechanical Ventilation in an Office

Hyun-Jae Chang, Shinsuke Kato, Tomoyuki Chikamoto

Open publisher page 7 citations

Abstract

The characteristics of a hybrid air-conditioning system, utilising natural and mechanical “task” ventilation, are investigated in an office setting. The characteristics of the indoor environment are examined by means of CFD (Computational Fluid Dynamics) simulations under various conditions of incoming outdoor air. The control of the task air conditioning system (VAV system) is included in the calculation through changing the supply air volume to keep the task zone‘s temperature at a target temperature. Results show that the thermal environment at the task zone is maintained comfortably with the aid of mechanical air conditioning and indoor air quality is achieved by providing natural ventilation through window opening. When the temperature of the in-flowing outdoor air rises and the vertical width of the window opening that lets in the air decreases, the inflow jet flows deeper into the room and therefore mixes easily with the indoor air. When the in-flowing outdoor air volume increases, the inflow jet exhibits a 3-dimensional aspect in a room. A vertical temperature gradient appears at the task zone with the increase of the temperature and volume of the in-flowing outdoor air. The distribution of the age of air is strongly influenced by the flow fields. The average age of air at the task zone depends mainly on the natural ventilation rate.

About this research paper

What this paper is about

The characteristics of a hybrid air-conditioning system, utilising natural and mechanical “task” ventilation, are investigated in an office setting. The characteristics of the indoor environment are examined by means of CFD (Computational Fluid Dynamics) simulations under various conditions of incoming outdoor air. The control of the task air conditioning system (VAV system) is included in the calculation through changing the supply air volume to keep the task zone‘s temperature at a target temperature. Results show that the thermal environment at the task zone is maintained comfortably with the aid of mechanical air conditioning and indoor air quality is achieved by providing natural ventilation through window opening. When the temperature of the in-flowing outdoor air rises and the vertical width of the window opening that lets in the air decreases, the inflow jet flows deeper into the room and therefore mixes easily with the indoor air. When the in-flowing outdoor air volume increases, the inflow jet exhibits a 3-dimensional aspect in a room. A vertical temperature gradient appears at the task zone with the increase of the temperature and volume of the in-flowing outdoor air. The distribution of the age of air is strongly influenced by the flow fields. The average age of air at the task zone depends mainly on the natural ventilation rate.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The characteristics of a hybrid air-conditioning system, utilising natural and mechanical “task” ventilation, are investigated in an office setting. The characteristics of the indoor environment are examined by means of CFD (Computational Fluid Dynamics) simulations under various conditions of incoming outdoor air. The control of the task air conditioning system (VAV system) is included in the calculation through changing the supply air volume to keep the task zone‘s temperature at a target temperature. Results show that the thermal environment at the task zone is maintained comfortably with the aid of mechanical air conditioning and indoor air quality is achieved by providing natural ventilation through window opening. When the temperature of the in-flowing outdoor air rises and the vertical width of the window opening that lets in the air decreases, the inflow jet flows deeper into the room and therefore mixes easily with the indoor air. When the in-flowing outdoor air volume increases, the inflow jet exhibits a 3-dimensional aspect in a room. A vertical temperature gradient appears at the task zone with the increase of the temperature and volume of the in-flowing outdoor air. The distribution of the age of air is strongly influenced by the flow fields. The average age of air at the task zone depends mainly on the natural ventilation rate.

Key concepts: Natural ventilation, Airflow, Thermal comfort, Air conditioning, Ventilation (architecture), Inflow, Environmental science, Indoor air quality

Related papers

Back to paper searchBrowse research topicsOriginal source
Room Air Distribution and Indoor Air Quality of Hybrid Air Conditioning System based on Natural and Mechanical Ventilation in an Office — Research Paper | ScholarLens