Extraction spectrophotometric determination of micro amounts of palladium(II) in catalysts
Shashikant H. Gaikwad, Tukaram N. Lokhande, Mansing A. Anuse
Abstract
Shashikant H. Gaikwad, Tukaram N. Lokhande, Mansing A. Anuse
Abstract
A new reagent, 4-(2'-furalideneimino)-3-methyl-5-mercapto-1,2,4-triazole, has been synthesized and used as a chromogenic reagent for palladium(II). Palladium(II) has been extracted as a yellow complex (λ max , 410 nm) from an aqueous solution at pH 5.4 with FIMMT in n-butanol. The molar extinction coefficient and Sandell's sensitivity are 1.4 ×10 3 L mol -1 cm -1 and 0.073 μg cm -2 , respectively. The effects of pH, reagent concentration, solvent, shaking time and stability of the complex have been studied. The complex system confirms to Beer's law over the range 5-50 ppm of palladium(II) with optimum range 17-50 ppm of the metal as evaluated from Ringbom's plot. The tolerance limit for many metal ions has been determined. The method has been applied successfully for the determination of palladium(II) in synthetic mixtures corresponding to alloys and palladium(II) in various hydrogenation catalysts.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new reagent, 4-(2'-furalideneimino)-3-methyl-5-mercapto-1,2,4-triazole, has been synthesized and used as a chromogenic reagent for palladium(II). Palladium(II) has been extracted as a yellow complex (λ max , 410 nm) from an aqueous solution at pH 5.4 with FIMMT in n-butanol. The molar extinction coefficient and Sandell's sensitivity are 1.4 ×10 3 L mol -1 cm -1 and 0.073 μg cm -2 , respectively. The effects of pH, reagent concentration, solvent, shaking time and stability of the complex have been studied. The complex system confirms to Beer's law over the range 5-50 ppm of palladium(II) with optimum range 17-50 ppm of the metal as evaluated from Ringbom's plot. The tolerance limit for many metal ions has been determined. The method has been applied successfully for the determination of palladium(II) in synthetic mixtures corresponding to alloys and palladium(II) in various hydrogenation catalysts.
Key concepts: Palladium, Reagent, Chemistry, Molar absorptivity, Chromogenic, Aqueous solution, Catalysis, Metal ions in aqueous solution