Solid phase extraction of trace amounts of zinc and cadmium ions using perlite as a supper sorbent
Mahmoud Roushani, Yar Mohammad Baghelani, S. Abbasi, Sepehr Mohammadi, Maryamosadat Mavaei
Abstract
Open-access reader
Mahmoud Roushani, Yar Mohammad Baghelani, S. Abbasi, Sepehr Mohammadi, Maryamosadat Mavaei
Abstract
Open-access reader
A novel method using a packed column with perlite as a new sorbent has been developed for preconcentration of trace amounts of zinc and cadmium prior to their determination by flame atomic absorption spectrometry. Several factors that may be affected on the solid phase extraction (SPE) process, such as pH, sample volume, flow rate, volume and concentration of eluent were studied and optimized. Linearity was maintained between 0.001–0.1 µg mL−1 for zinc, and 0.001–0.3 µg mL−1 for cadmium. Detection limits based on 3Sb for zinc and cadmium were 1.8 and 1.6 ng mL−1, respectively. The relative standard deviations of eight replicate measurements of 0.02 µg mL−1 of zinc and 0.05 µg mL−1 of cadmium ions were 2.1% and 1.8%, respectively. Finally, the developed method was successfully applied to extraction and determination of the zinc and cadmium ions in the water and food samples and satisfactory results were obtained. KEY WORDS: Solid phase extraction, Zinc determination, Cadmium determination, Preconcentration, Perlite Bull. Chem. Soc. Ethiop. 2016, 30(2), 175-184.DOI: http://dx.doi.org/10.4314/bcse.v30i2.2
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel method using a packed column with perlite as a new sorbent has been developed for preconcentration of trace amounts of zinc and cadmium prior to their determination by flame atomic absorption spectrometry. Several factors that may be affected on the solid phase extraction (SPE) process, such as pH, sample volume, flow rate, volume and concentration of eluent were studied and optimized. Linearity was maintained between 0.001–0.1 µg mL−1 for zinc, and 0.001–0.3 µg mL−1 for cadmium. Detection limits based on 3Sb for zinc and cadmium were 1.8 and 1.6 ng mL−1, respectively. The relative standard deviations of eight replicate measurements of 0.02 µg mL−1 of zinc and 0.05 µg mL−1 of cadmium ions were 2.1% and 1.8%, respectively. Finally, the developed method was successfully applied to extraction and determination of the zinc and cadmium ions in the water and food samples and satisfactory results were obtained. KEY WORDS: Solid phase extraction, Zinc determination, Cadmium determination, Preconcentration, Perlite Bull. Chem. Soc. Ethiop. 2016, 30(2), 175-184.DOI: http://dx.doi.org/10.4314/bcse.v30i2.2
Key concepts: Chemistry, Cadmium, Sorbent, Zinc, Perlite, Solid phase extraction, Extraction (chemistry), Detection limit