1981University of North Texas Digital Library (University of North Texas)Open access

In-line measurement of plutonium and americium in mixed solutions

T.K. Li

Open full text 0 citations

Abstract

A solution assay instrument (SAI) has been developed at the Los Alamos National Laboratory and installed in the plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument is designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and Am/Pu ratios. For a 25-mL sample, the assay precision is < 1%, both for plutonium and for americium having concentrations >5 g/L within a 2000-s count time.

Open-access reader

About this research paper

What this paper is about

A solution assay instrument (SAI) has been developed at the Los Alamos National Laboratory and installed in the plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument is designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and Am/Pu ratios. For a 25-mL sample, the assay precision is < 1%, both for plutonium and for americium having concentrations >5 g/L within a 2000-s count time.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A solution assay instrument (SAI) has been developed at the Los Alamos National Laboratory and installed in the plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument is designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and Am/Pu ratios. For a 25-mL sample, the assay precision is < 1%, both for plutonium and for americium having concentrations >5 g/L within a 2000-s count time.

Key concepts: Plutonium, Americium, National laboratory, Nuclear reprocessing, Plutonium-240, Nuclear engineering, Radiochemistry, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
In-line measurement of plutonium and americium in mixed solutions — Research Paper | ScholarLens