2016PubMedOpen access

The Pupillary Light Reflex in Idiopathic Intracranial Hypertension.

Jason C. Park, Heather E. Moss, J. Jason McAnany

Open full text 36 citations

Abstract

PURPOSE: To evaluate the effects of idiopathic intracranial hypertension (IIH) on rod-, cone-, and melanopsin-mediated pupillary light reflexes (PLRs). METHODS: Pupillary light reflexes elicited by full-field, brief-flash stimuli were recorded in 13 IIH patients and 13 normal controls. Subjects were dark-adapted for 10 minutes and the PLR was recorded in response to short-wavelength flashes (0.001 cd/m2: rod condition; 450 cd/m2: melanopsin condition). Subjects were then exposed to a rod-suppressing field and 10 cd/m2 long-wavelength flashes were presented (cone condition). Pupillary light reflexes were quantified as the maximum transient constriction (rod and cone conditions) and the post-illumination pupil constriction (melanopsin condition), relative to the baseline pupil size. Diagnostic power was evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The IIH patients had significantly smaller PLRs under the melanopsin (P < 0.001) and rod (P = 0.04) paradigms; a trend for reduced cone-mediated PLRs was also found (P = 0.08). Receiver operating characteristic analysis indicated areas under the curves (AUC) of 0.83 (melanopsin-meditated; P = 0.001), 0.71 (rod-mediated; P = 0.07), and 0.77 (cone-mediated; P = 0.02). The AUC (0.90, P < 0.001), sensitivity (85%), and specificity (85%) were high for ROC analysis performed on the mean of the rod, cone, and melanopsin PLRs. CONCLUSIONS: Pupillary light reflex reductions in IIH patients indicate compromised RGC function. PLR measurement, particularly under rod- and melanopsin-mediated conditions, may be a useful adjunct to standard clinical measures of visual function in IIH.

About this research paper

What this paper is about

PURPOSE: To evaluate the effects of idiopathic intracranial hypertension (IIH) on rod-, cone-, and melanopsin-mediated pupillary light reflexes (PLRs). METHODS: Pupillary light reflexes elicited by full-field, brief-flash stimuli were recorded in 13 IIH patients and 13 normal controls. Subjects were dark-adapted for 10 minutes and the PLR was recorded in response to short-wavelength flashes (0.001 cd/m2: rod condition; 450 cd/m2: melanopsin condition). Subjects were then exposed to a rod-suppressing field and 10 cd/m2 long-wavelength flashes were presented (cone condition). Pupillary light reflexes were quantified as the maximum transient constriction (rod and cone conditions) and the post-illumination pupil constriction (melanopsin condition), relative to the baseline pupil size. Diagnostic power was evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The IIH patients had significantly smaller PLRs under the melanopsin (P < 0.001) and rod (P = 0.04) paradigms; a trend for reduced cone-mediated PLRs was also found (P = 0.08). Receiver operating characteristic analysis indicated areas under the curves (AUC) of 0.83 (melanopsin-meditated; P = 0.001), 0.71 (rod-mediated; P = 0.07), and 0.77 (cone-mediated; P = 0.02). The AUC (0.90, P < 0.001), sensitivity (85%), and specificity (85%) were high for ROC analysis performed on the mean of the rod, cone, and melanopsin PLRs. CONCLUSIONS: Pupillary light reflex reductions in IIH patients indicate compromised RGC function. PLR measurement, particularly under rod- and melanopsin-mediated conditions, may be a useful adjunct to standard clinical measures of visual function in IIH.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the effects of idiopathic intracranial hypertension (IIH) on rod-, cone-, and melanopsin-mediated pupillary light reflexes (PLRs). METHODS: Pupillary light reflexes elicited by full-field, brief-flash stimuli were recorded in 13 IIH patients and 13 normal controls. Subjects were dark-adapted for 10 minutes and the PLR was recorded in response to short-wavelength flashes (0.001 cd/m2: rod condition; 450 cd/m2: melanopsin condition). Subjects were then exposed to a rod-suppressing field and 10 cd/m2 long-wavelength flashes were presented (cone condition). Pupillary light reflexes were quantified as the maximum transient constriction (rod and cone conditions) and the post-illumination pupil constriction (melanopsin condition), relative to the baseline pupil size. Diagnostic power was evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The IIH patients had significantly smaller PLRs under the melanopsin (P < 0.001) and rod (P = 0.04) paradigms; a trend for reduced cone-mediated PLRs was also found (P = 0.08). Receiver operating characteristic analysis indicated areas under the curves (AUC) of 0.83 (melanopsin-meditated; P = 0.001), 0.71 (rod-mediated; P = 0.07), and 0.77 (cone-mediated; P = 0.02). The AUC (0.90, P < 0.001), sensitivity (85%), and specificity (85%) were high for ROC analysis performed on the mean of the rod, cone, and melanopsin PLRs. CONCLUSIONS: Pupillary light reflex reductions in IIH patients indicate compromised RGC function. PLR measurement, particularly under rod- and melanopsin-mediated conditions, may be a useful adjunct to standard clinical measures of visual function in IIH.

Key concepts: Melanopsin, Pupillary light reflex, Pupillary reflex, Pupillary response, Pupil, Reflex, Ophthalmology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The Pupillary Light Reflex in Idiopathic Intracranial Hypertension. — Research Paper | ScholarLens