2012•International Conference on Mechanic Automation and Control EngineeringRequires access

Experimental Revision of the Multi-circuit Ampacity Correction Factor of Direct Buried 10 kV Three-core Cables

Cheng Chen, Haiqing Niu, Yong Hua You, Yao Zhang, Jiguang Zhao, Qunfeng Zhang

Open publisher page 1 citations

Abstract

Cable load is adjusted according to its ampacity, therefore the accurate calculation of ampacity ensure the cable operate safely and reliably. For 10kV distribution cables (general three-core cable), the ampacity is the product of standard one (under standard condition) multiplying by its correction factor. Nowadays, more and more cable operation personnel question the applicability of those factors, especially the multi-circuit ampacity correction factor. A program calculating the ampacity of three-core cable with directly buried laying is developed. Ampacity tests of single and four circuit cable are undertaken in this paper. Test results shows consistent with that calculated, which verifies the correctness of the theoretical calculation. Studies show that the multicircuit ampacity correction factors used currently are too large and hreaten its operation safety. On the basis of calculation and experiments, this paper recommends the multi-circuit ampacity correction factors for the directly buried 10kV threecore cable.

About this research paper

What this paper is about

Cable load is adjusted according to its ampacity, therefore the accurate calculation of ampacity ensure the cable operate safely and reliably. For 10kV distribution cables (general three-core cable), the ampacity is the product of standard one (under standard condition) multiplying by its correction factor. Nowadays, more and more cable operation personnel question the applicability of those factors, especially the multi-circuit ampacity correction factor. A program calculating the ampacity of three-core cable with directly buried laying is developed. Ampacity tests of single and four circuit cable are undertaken in this paper. Test results shows consistent with that calculated, which verifies the correctness of the theoretical calculation. Studies show that the multicircuit ampacity correction factors used currently are too large and hreaten its operation safety. On the basis of calculation and experiments, this paper recommends the multi-circuit ampacity correction factors for the directly buried 10kV threecore cable.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cable load is adjusted according to its ampacity, therefore the accurate calculation of ampacity ensure the cable operate safely and reliably. For 10kV distribution cables (general three-core cable), the ampacity is the product of standard one (under standard condition) multiplying by its correction factor. Nowadays, more and more cable operation personnel question the applicability of those factors, especially the multi-circuit ampacity correction factor. A program calculating the ampacity of three-core cable with directly buried laying is developed. Ampacity tests of single and four circuit cable are undertaken in this paper. Test results shows consistent with that calculated, which verifies the correctness of the theoretical calculation. Studies show that the multicircuit ampacity correction factors used currently are too large and hreaten its operation safety. On the basis of calculation and experiments, this paper recommends the multi-circuit ampacity correction factors for the directly buried 10kV threecore cable.

Key concepts: Ampacity, Core (optical fiber), Electrical engineering, Single-core, Engineering, Reliability engineering, Computer science, Electrical conductor

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Revision of the Multi-circuit Ampacity Correction Factor of Direct Buried 10 kV Three-core Cables — Research Paper | ScholarLens