2008PubMedRequires access

[Chemiluminescence determination of 6-mercaptopurine in the luminol-potassium ferricyanide system].

Tao Wang, Bingchun Xue, Erbao Liu

Open publisher page 2 citations

Abstract

A novel chemiluminescence (CL) method to determine 6-mercaptopurine (6-MP) is described, based on the catalytic effect of 6-MP on the CL reaction of luminol with K3Fe(C-N)6 in a flow system. Under optimal experimental conditions, the calibration graph is linear in the range of 1.02 x 10(-7) to 1.02 x 10(-9) mol x L(-1) 6-MP. The linear regression equation was Y = 36.315c + 140.72, where Y is the relative emission intensity and c is the concentration of 6-MP expressed in 10(-8) mol x L(-1) and the correlation coefficient is 0. 998 2 with the detection limits of 6. 33 X 10(-10) mol x L(-1) (S/N = 3). CL peak-height precision is 3.54% of RSD (n = 12) for a level of 2.0 x 10(-9) mol x L(-1). This method satisfactorily provides a fast, simple, sensible and favorable technique for the determination of 6-MP in synthesized samples in implementation. Moreover, the possible mechanism of CL enhancement was briefly discussed. Obviously, the reaction was related to the formation of free radicals. Thus, the CL emission could preliminarily be attributed to the process of energy transfer due to O2. radical and * OH radical resulting from the oxidation product of 6-MP by K3Fe(CN)6, which acts as an active intermediate that reacts with luminol, leading to the formation of excited luminol molecule, which gives out an emission when it returns to its ground state.

About this research paper

What this paper is about

A novel chemiluminescence (CL) method to determine 6-mercaptopurine (6-MP) is described, based on the catalytic effect of 6-MP on the CL reaction of luminol with K3Fe(C-N)6 in a flow system. Under optimal experimental conditions, the calibration graph is linear in the range of 1.02 x 10(-7) to 1.02 x 10(-9) mol x L(-1) 6-MP. The linear regression equation was Y = 36.315c + 140.72, where Y is the relative emission intensity and c is the concentration of 6-MP expressed in 10(-8) mol x L(-1) and the correlation coefficient is 0. 998 2 with the detection limits of 6. 33 X 10(-10) mol x L(-1) (S/N = 3). CL peak-height precision is 3.54% of RSD (n = 12) for a level of 2.0 x 10(-9) mol x L(-1). This method satisfactorily provides a fast, simple, sensible and favorable technique for the determination of 6-MP in synthesized samples in implementation. Moreover, the possible mechanism of CL enhancement was briefly discussed. Obviously, the reaction was related to the formation of free radicals. Thus, the CL emission could preliminarily be attributed to the process of energy transfer due to O2. radical and * OH radical resulting from the oxidation product of 6-MP by K3Fe(CN)6, which acts as an active intermediate that reacts with luminol, leading to the formation of excited luminol molecule, which gives out an emission when it returns to its ground state.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel chemiluminescence (CL) method to determine 6-mercaptopurine (6-MP) is described, based on the catalytic effect of 6-MP on the CL reaction of luminol with K3Fe(C-N)6 in a flow system. Under optimal experimental conditions, the calibration graph is linear in the range of 1.02 x 10(-7) to 1.02 x 10(-9) mol x L(-1) 6-MP. The linear regression equation was Y = 36.315c + 140.72, where Y is the relative emission intensity and c is the concentration of 6-MP expressed in 10(-8) mol x L(-1) and the correlation coefficient is 0. 998 2 with the detection limits of 6. 33 X 10(-10) mol x L(-1) (S/N = 3). CL peak-height precision is 3.54% of RSD (n = 12) for a level of 2.0 x 10(-9) mol x L(-1). This method satisfactorily provides a fast, simple, sensible and favorable technique for the determination of 6-MP in synthesized samples in implementation. Moreover, the possible mechanism of CL enhancement was briefly discussed. Obviously, the reaction was related to the formation of free radicals. Thus, the CL emission could preliminarily be attributed to the process of energy transfer due to O2. radical and * OH radical resulting from the oxidation product of 6-MP by K3Fe(CN)6, which acts as an active intermediate that reacts with luminol, leading to the formation of excited luminol molecule, which gives out an emission when it returns to its ground state.

Key concepts: Chemiluminescence, Luminol, Chemistry, Potassium ferricyanide, Radical, Analytical Chemistry (journal), Excited state, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
[Chemiluminescence determination of 6-mercaptopurine in the luminol-potassium ferricyanide system]. — Research Paper | ScholarLens