2008PubMedRequires access

[Detection of Haemophilus influenzae by multiplex polymerase chain reaction method].

Guozhong Tian, Zhu-jun Shao, Li Zhang, Xiaojing Li, Bingqing Zhu, Ya-jing Yang, Xu Li, Yuan Gao, Xiaolei Wang

Open publisher page 1 citations

Abstract

OBJECTIVE: To develop a rapid method for detecting Haemophilus influenzae by multiplex polymerase chain reaction (M-PCR). METHODS: Primers (Hi) were designed for amplification of p6 gene coding P6 protein of Haemophilus influenzae, which was used to identify Haemophilus influenzae species. Primers (Hi-cap) were designed for amplification of bexA gene which coding capsular polysaccharide (cap) synthesis was used for detecting whether Haemophilus influenzae isolates possess bexA gene relating to cap synthesis. Twelve primers (Hia-Hif) were designed for amplification of cap synthesis gene to identify the cap-type of Haemophilus influenzae. Other relative enteric pathogenic bacteria were amplified by M-PCR to serve as controls. 200 strains isolated from patients were identified. Results from M-PCR were compared to two methods including V and X factors grow requirement test and standard slide agglutination serotyping (SAST). RESULTS: The results indicated that the M-PCR assay was high specificity and sensitivity and might be valuable for differential diagnosis of Haemophilus influenzae. The sensitivity of detection was 0.935 pg. 189 strains out of the 200 belonged to Haemophilus influenzae isolates, and one isolate was cap-type f. An agreement results were seen among the V and X factors grow requirement test, SAST and M-PCR methods. CONCLUSION: M-PCR method showed satisfactory sensitivity, specificity and stability for detecting and identifying Haemophilus influenzae, and could be used in clinic diagnosis, surveillance and rapid diagnosis for plague of Haemophilus influenzae.

About this research paper

What this paper is about

OBJECTIVE: To develop a rapid method for detecting Haemophilus influenzae by multiplex polymerase chain reaction (M-PCR). METHODS: Primers (Hi) were designed for amplification of p6 gene coding P6 protein of Haemophilus influenzae, which was used to identify Haemophilus influenzae species. Primers (Hi-cap) were designed for amplification of bexA gene which coding capsular polysaccharide (cap) synthesis was used for detecting whether Haemophilus influenzae isolates possess bexA gene relating to cap synthesis. Twelve primers (Hia-Hif) were designed for amplification of cap synthesis gene to identify the cap-type of Haemophilus influenzae. Other relative enteric pathogenic bacteria were amplified by M-PCR to serve as controls. 200 strains isolated from patients were identified. Results from M-PCR were compared to two methods including V and X factors grow requirement test and standard slide agglutination serotyping (SAST). RESULTS: The results indicated that the M-PCR assay was high specificity and sensitivity and might be valuable for differential diagnosis of Haemophilus influenzae. The sensitivity of detection was 0.935 pg. 189 strains out of the 200 belonged to Haemophilus influenzae isolates, and one isolate was cap-type f. An agreement results were seen among the V and X factors grow requirement test, SAST and M-PCR methods. CONCLUSION: M-PCR method showed satisfactory sensitivity, specificity and stability for detecting and identifying Haemophilus influenzae, and could be used in clinic diagnosis, surveillance and rapid diagnosis for plague of Haemophilus influenzae.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To develop a rapid method for detecting Haemophilus influenzae by multiplex polymerase chain reaction (M-PCR). METHODS: Primers (Hi) were designed for amplification of p6 gene coding P6 protein of Haemophilus influenzae, which was used to identify Haemophilus influenzae species. Primers (Hi-cap) were designed for amplification of bexA gene which coding capsular polysaccharide (cap) synthesis was used for detecting whether Haemophilus influenzae isolates possess bexA gene relating to cap synthesis. Twelve primers (Hia-Hif) were designed for amplification of cap synthesis gene to identify the cap-type of Haemophilus influenzae. Other relative enteric pathogenic bacteria were amplified by M-PCR to serve as controls. 200 strains isolated from patients were identified. Results from M-PCR were compared to two methods including V and X factors grow requirement test and standard slide agglutination serotyping (SAST). RESULTS: The results indicated that the M-PCR assay was high specificity and sensitivity and might be valuable for differential diagnosis of Haemophilus influenzae. The sensitivity of detection was 0.935 pg. 189 strains out of the 200 belonged to Haemophilus influenzae isolates, and one isolate was cap-type f. An agreement results were seen among the V and X factors grow requirement test, SAST and M-PCR methods. CONCLUSION: M-PCR method showed satisfactory sensitivity, specificity and stability for detecting and identifying Haemophilus influenzae, and could be used in clinic diagnosis, surveillance and rapid diagnosis for plague of Haemophilus influenzae.

Key concepts: Haemophilus influenzae, Haemophilus, Microbiology, Polymerase chain reaction, Serotype, Multiplex polymerase chain reaction, Biology, Pasteurellaceae

Related papers

Back to paper searchBrowse research topicsOriginal source
[Detection of Haemophilus influenzae by multiplex polymerase chain reaction method]. — Research Paper | ScholarLens