2016Journal of GlaucomaRequires access

Modified Scleral Tunnel to Prevent Tube Exposure in Patients With Refractory Glaucoma

Xiaohua Ma, Xiujuan Du, Bing Liu, Hongsheng Bi

Open publisher page 16 citations

Abstract

PURPOSE: To present and evaluate modified scleral tunnel in prevention of tube exposure following Ahmed valve implantation in refractory glaucoma. METHODS: In the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, a retrospective study was conducted in 36 eyes of 34 patients who were diagnosed with refractory glaucoma and underwent Ahmed glaucoma valve implantation. In the surgery, the modified scleral tunnel was done to prevent tube exposure. RESULTS: At the end of follow-up (mean 21.68±9.25 mo), there was no conjunctival tube exposure in all 36 eyes. The mean intraocular pressure was 18.3±6.79 mmHg, and 8 eyes needed 1 to 3 types of drugs to decrease intraocular pressure. CONCLUSIONS: The modified scleral tunnel technique in Ahmed glaucoma valve implantation is able to prevent conjunctival tube exposure in the patients with refractory glaucoma.

About this research paper

What this paper is about

PURPOSE: To present and evaluate modified scleral tunnel in prevention of tube exposure following Ahmed valve implantation in refractory glaucoma. METHODS: In the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, a retrospective study was conducted in 36 eyes of 34 patients who were diagnosed with refractory glaucoma and underwent Ahmed glaucoma valve implantation. In the surgery, the modified scleral tunnel was done to prevent tube exposure. RESULTS: At the end of follow-up (mean 21.68±9.25 mo), there was no conjunctival tube exposure in all 36 eyes. The mean intraocular pressure was 18.3±6.79 mmHg, and 8 eyes needed 1 to 3 types of drugs to decrease intraocular pressure. CONCLUSIONS: The modified scleral tunnel technique in Ahmed glaucoma valve implantation is able to prevent conjunctival tube exposure in the patients with refractory glaucoma.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To present and evaluate modified scleral tunnel in prevention of tube exposure following Ahmed valve implantation in refractory glaucoma. METHODS: In the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, a retrospective study was conducted in 36 eyes of 34 patients who were diagnosed with refractory glaucoma and underwent Ahmed glaucoma valve implantation. In the surgery, the modified scleral tunnel was done to prevent tube exposure. RESULTS: At the end of follow-up (mean 21.68±9.25 mo), there was no conjunctival tube exposure in all 36 eyes. The mean intraocular pressure was 18.3±6.79 mmHg, and 8 eyes needed 1 to 3 types of drugs to decrease intraocular pressure. CONCLUSIONS: The modified scleral tunnel technique in Ahmed glaucoma valve implantation is able to prevent conjunctival tube exposure in the patients with refractory glaucoma.

Key concepts: Medicine, Glaucoma valve, Glaucoma, Intraocular pressure, Refractory (planetary science), Ophthalmology, Surgery, Glaucoma medication

Related papers

Back to paper searchBrowse research topicsOriginal source
Modified Scleral Tunnel to Prevent Tube Exposure in Patients With Refractory Glaucoma — Research Paper | ScholarLens