99mTc-MIBI and 99mTc-MDP scintimammography for detecting breast carcinoma.
Shaoliang Chen, Wenjun Liu, Yilei Mao, Wei Zhu, Zhi Yao, Xin Sun, Yanghui Xiu, Yong Yin, J. Chen
Abstract
Shaoliang Chen, Wenjun Liu, Yilei Mao, Wei Zhu, Zhi Yao, Xin Sun, Yanghui Xiu, Yong Yin, J. Chen
Abstract
OBJECTIVE: To assess the value of scintimammography with both 99mTc-MIBI and 99mTc-MDP in detecting breast cancer. METHODS: A total of 35 women with clinical findings of suspicious breast lesions were studied with both 99mTc-MIBI and 99mTc-MDP scintimammography. All patients underwent surgery within one week and the final diagnostic results (histopathological) were obtained. RESULTS: Eighteen of 35 abnormalities of breast were pathologically confirmed as breast cancer and 17 as benigN lesions. In this group of patients studied, the sensitivity, specificity and accuracy of 99mTc-MIBI scintimammography were 77.8%, 88.2% and 82.9%, respectively and those of 99mTc-MDP scintimammography were 72.2%, 88.2% and 80.0%, respectively. There was no significant difference between 99mTc-MIBI and 99mTc-MDP scintimammography. CONCLUSION: This study showed the high diagnostic accuracy of both 99mTc-MIBI and 99mTc-MDP scintimammography in detecting breast cancer. Both can be used as non-invasively assess breast cancer invasiveness before surgery.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To assess the value of scintimammography with both 99mTc-MIBI and 99mTc-MDP in detecting breast cancer. METHODS: A total of 35 women with clinical findings of suspicious breast lesions were studied with both 99mTc-MIBI and 99mTc-MDP scintimammography. All patients underwent surgery within one week and the final diagnostic results (histopathological) were obtained. RESULTS: Eighteen of 35 abnormalities of breast were pathologically confirmed as breast cancer and 17 as benigN lesions. In this group of patients studied, the sensitivity, specificity and accuracy of 99mTc-MIBI scintimammography were 77.8%, 88.2% and 82.9%, respectively and those of 99mTc-MDP scintimammography were 72.2%, 88.2% and 80.0%, respectively. There was no significant difference between 99mTc-MIBI and 99mTc-MDP scintimammography. CONCLUSION: This study showed the high diagnostic accuracy of both 99mTc-MIBI and 99mTc-MDP scintimammography in detecting breast cancer. Both can be used as non-invasively assess breast cancer invasiveness before surgery.
Key concepts: Scintimammography, Medicine, Breast cancer, Breast carcinoma, Nuclear medicine, Radiology, Cancer, Scintigraphy