2016•Magnetic Resonance in MedicineOpen access

Transverse relaxation and flip angle mapping: Evaluation of simultaneous and independent methods using multiple spin echoes

Kelly C. McPhee, Alan H. Wilman

Open full text 54 citations

Abstract

PURPOSE: To evaluate transverse relaxation (T2) and flip angle maps derived from signal pathway modeling of multiple spin echoes using simultaneous or independent T2 and flip angle fitting. METHODS: We examined different approaches to indirect and stimulated echo compensated T2 relaxometry from multiple spin echoes to evaluate both T2 and flip angle accuracy in simulation, phantom, and human brain. Signal pathways were modeled with or without independent flip angle maps using either Bloch simulations, or Extended Phase Graph (EPG) with Fourier or Shinnar-Le Roux approximation of slice profiles. RESULTS: Slice-selective decay curves differ substantially between models. Inaccurate flip angles are obtained with EPG methods, although T2 values are relatively accurate. Providing measured flip angles to EPG methods yields erroneous T2. Bloch methods improve both T2 and flip angle results. Simultaneous fitting can suffer from flip angle redundancy yielding multiple T2 solutions, particularly in low signal-to-noise ratio cases. CONCLUSION: EPG fitting provides reasonably accurate T2, but is limited by poor accuracy in resulting flip angles, and T2 errors increase when flip angles are provided. Bloch simultaneous fitting of T2 and flip angle provides excellent results, but can be limited by multiple solutions which can be overcome by including a flip angle map. Magn Reson Med 77:2057-2065, 2017. © 2016 International Society for MagneticResonance in Medicine.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To evaluate transverse relaxation (T2) and flip angle maps derived from signal pathway modeling of multiple spin echoes using simultaneous or independent T2 and flip angle fitting. METHODS: We examined different approaches to indirect and stimulated echo compensated T2 relaxometry from multiple spin echoes to evaluate both T2 and flip angle accuracy in simulation, phantom, and human brain. Signal pathways were modeled with or without independent flip angle maps using either Bloch simulations, or Extended Phase Graph (EPG) with Fourier or Shinnar-Le Roux approximation of slice profiles. RESULTS: Slice-selective decay curves differ substantially between models. Inaccurate flip angles are obtained with EPG methods, although T2 values are relatively accurate. Providing measured flip angles to EPG methods yields erroneous T2. Bloch methods improve both T2 and flip angle results. Simultaneous fitting can suffer from flip angle redundancy yielding multiple T2 solutions, particularly in low signal-to-noise ratio cases. CONCLUSION: EPG fitting provides reasonably accurate T2, but is limited by poor accuracy in resulting flip angles, and T2 errors increase when flip angles are provided. Bloch simultaneous fitting of T2 and flip angle provides excellent results, but can be limited by multiple solutions which can be overcome by including a flip angle map. Magn Reson Med 77:2057-2065, 2017. © 2016 International Society for MagneticResonance in Medicine.

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate transverse relaxation (T2) and flip angle maps derived from signal pathway modeling of multiple spin echoes using simultaneous or independent T2 and flip angle fitting. METHODS: We examined different approaches to indirect and stimulated echo compensated T2 relaxometry from multiple spin echoes to evaluate both T2 and flip angle accuracy in simulation, phantom, and human brain. Signal pathways were modeled with or without independent flip angle maps using either Bloch simulations, or Extended Phase Graph (EPG) with Fourier or Shinnar-Le Roux approximation of slice profiles. RESULTS: Slice-selective decay curves differ substantially between models. Inaccurate flip angles are obtained with EPG methods, although T2 values are relatively accurate. Providing measured flip angles to EPG methods yields erroneous T2. Bloch methods improve both T2 and flip angle results. Simultaneous fitting can suffer from flip angle redundancy yielding multiple T2 solutions, particularly in low signal-to-noise ratio cases. CONCLUSION: EPG fitting provides reasonably accurate T2, but is limited by poor accuracy in resulting flip angles, and T2 errors increase when flip angles are provided. Bloch simultaneous fitting of T2 and flip angle provides excellent results, but can be limited by multiple solutions which can be overcome by including a flip angle map. Magn Reson Med 77:2057-2065, 2017. © 2016 International Society for MagneticResonance in Medicine.

Key concepts: Flip angle, Transverse plane, Nuclear magnetic resonance, Relaxation (psychology), Physics, Flip, Fast spin echo, Transverse magnetic

Related papers

Back to paper searchBrowse research topicsOriginal source
Transverse relaxation and flip angle mapping: Evaluation of simultaneous and independent methods using multiple spin echoes — Research Paper | ScholarLens