[AC and DC electroretinography in degenerative retinal diseases].

Ulrich Kellner, MH Foerster

Open publisher page 1 citations

Abstract

In clinical electrophysiology AC-recorded ERGs are used for the investigation of a- and b-wave parameters. The direct coupled (DC-ERG) ist used to record the c-wave. Theoretically the DC-ERG technique has less influence on the recorded potentials than the AC-ERG technique. We recorded AC- and DC-ERGs of 20 normal eyes, 17 eyes with x-linked congenital retinoschisis and 30 eyes with retinal degenerations. In normal eyes no difference was found between AC- und DC-ERG concerning a- and b-wave amplitudes, latencies and implicit times, the b/a-ratios and the oscillatory potentials. The 30 Hz flicker amplitude was higher in the DC-ERG (p less than 0.0003). The intraindividual variability of all measured parameters was comparable between AC- and DC-ERG. In x-linked retinoschisis the b-wave amplitudes and the b/a-ratios were lower in the DC-ERG than in the AC-ERG. In retinal degenerative diseases the a-wave amplitudes were higher and the dark-adapted b-wave amplitudes lower in the DC-ERG, therefore the b/a-ratio was lower in the DC-ERG. We conclude, the DC-ERG is a reproducible method for clinical routine investigations. It is comparable to the conventional AC-ERG technique. In certain diseases the pathological features of the electroretinogram were more distinct in the DC-ERG than the AC-ERG.

About this research paper

What this paper is about

In clinical electrophysiology AC-recorded ERGs are used for the investigation of a- and b-wave parameters. The direct coupled (DC-ERG) ist used to record the c-wave. Theoretically the DC-ERG technique has less influence on the recorded potentials than the AC-ERG technique. We recorded AC- and DC-ERGs of 20 normal eyes, 17 eyes with x-linked congenital retinoschisis and 30 eyes with retinal degenerations. In normal eyes no difference was found between AC- und DC-ERG concerning a- and b-wave amplitudes, latencies and implicit times, the b/a-ratios and the oscillatory potentials. The 30 Hz flicker amplitude was higher in the DC-ERG (p less than 0.0003). The intraindividual variability of all measured parameters was comparable between AC- and DC-ERG. In x-linked retinoschisis the b-wave amplitudes and the b/a-ratios were lower in the DC-ERG than in the AC-ERG. In retinal degenerative diseases the a-wave amplitudes were higher and the dark-adapted b-wave amplitudes lower in the DC-ERG, therefore the b/a-ratio was lower in the DC-ERG. We conclude, the DC-ERG is a reproducible method for clinical routine investigations. It is comparable to the conventional AC-ERG technique. In certain diseases the pathological features of the electroretinogram were more distinct in the DC-ERG than the AC-ERG.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In clinical electrophysiology AC-recorded ERGs are used for the investigation of a- and b-wave parameters. The direct coupled (DC-ERG) ist used to record the c-wave. Theoretically the DC-ERG technique has less influence on the recorded potentials than the AC-ERG technique. We recorded AC- and DC-ERGs of 20 normal eyes, 17 eyes with x-linked congenital retinoschisis and 30 eyes with retinal degenerations. In normal eyes no difference was found between AC- und DC-ERG concerning a- and b-wave amplitudes, latencies and implicit times, the b/a-ratios and the oscillatory potentials. The 30 Hz flicker amplitude was higher in the DC-ERG (p less than 0.0003). The intraindividual variability of all measured parameters was comparable between AC- and DC-ERG. In x-linked retinoschisis the b-wave amplitudes and the b/a-ratios were lower in the DC-ERG than in the AC-ERG. In retinal degenerative diseases the a-wave amplitudes were higher and the dark-adapted b-wave amplitudes lower in the DC-ERG, therefore the b/a-ratio was lower in the DC-ERG. We conclude, the DC-ERG is a reproducible method for clinical routine investigations. It is comparable to the conventional AC-ERG technique. In certain diseases the pathological features of the electroretinogram were more distinct in the DC-ERG than the AC-ERG.

Key concepts: Erg, Electroretinography, Retinoschisis, Amplitude, Physics, Retinal, Ophthalmology, Optics