Study on Enzyme Immunoassays for the Measurement of Thyroglobulin and Anti-Thyroglobulin Autoantibody in Human Serum
S Ohtaki, Yuichi Endo
Abstract
Open-access reader
S Ohtaki, Yuichi Endo
Abstract
Open-access reader
Enzyme-linked sandwich immunoassays for the measurement of thyroglobulin and anti-thyroglobulin autoantibody in human serum using silicone rod and beta-D-galactosidase were studied. These methods showed excellent results in specificity, sensitivity, precision and clinical application. 1) A method using silicone rod coated with rabbit (anti-human thyroglobulin) immunoglobulin G and rabbit (anti-human thyroglobulin) monovalent fragment of immunoglobulin G (Fab') conjugated with beta-D-galactosidase was developed for the measurement of circulating thyroglobulin. The sensitivity of the assay with as little as 2 microliter of serum was 10.7 amoles/tube corresponding to 3.5 ng/ml of serum, which was equal to or rather higher than that of radioimmunoassay. The correlation coefficient between values determined by the present assay and a double-antibody radioimmunoassay was 0.99 (n = 63, p less than 0.001). Circulating thyroglobulin was detectable in 90% of 146 normal subjects, the concentration being 13.3 +/- 10.3 ng/ml (mean +/- S.D.). Interference of anti-thyroglobulin autoantibody with the assay for thyroglobulin was smaller than that in radioimmunoassay. 2) Another method using human thyroglobulin conjugated with beta-D-galactosidase and silicone rod coated with human thyroglobulin was developed for the measurement of circulating (anti-human thyroglobulin) autoantibody. The sensitivity of the assay with as little as 5 microliter of serum was 7 fmoles/tube corresponding to 220 ng/ml of serum, which was equal to or rather higher than that of radioimmunoassay. The highly significant correlation was observed between the concentrations of anti-thyroglobulin autoantibody determined by the present assay and a radioimmunoassay (r = 0.80, n = 74, p less than 0.001) and also between those by the present assay and those by tanned red cell hemagglutination (r = 0.78, n = 199, p less than 0.001). No effect of thyroglobulin on the present assay was observed unless the ratio of the amount of thyroglobulin to that of (anti-human thyroglobulin) immunoglobulin G was higher than a tenth.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Enzyme-linked sandwich immunoassays for the measurement of thyroglobulin and anti-thyroglobulin autoantibody in human serum using silicone rod and beta-D-galactosidase were studied. These methods showed excellent results in specificity, sensitivity, precision and clinical application. 1) A method using silicone rod coated with rabbit (anti-human thyroglobulin) immunoglobulin G and rabbit (anti-human thyroglobulin) monovalent fragment of immunoglobulin G (Fab') conjugated with beta-D-galactosidase was developed for the measurement of circulating thyroglobulin. The sensitivity of the assay with as little as 2 microliter of serum was 10.7 amoles/tube corresponding to 3.5 ng/ml of serum, which was equal to or rather higher than that of radioimmunoassay. The correlation coefficient between values determined by the present assay and a double-antibody radioimmunoassay was 0.99 (n = 63, p less than 0.001). Circulating thyroglobulin was detectable in 90% of 146 normal subjects, the concentration being 13.3 +/- 10.3 ng/ml (mean +/- S.D.). Interference of anti-thyroglobulin autoantibody with the assay for thyroglobulin was smaller than that in radioimmunoassay. 2) Another method using human thyroglobulin conjugated with beta-D-galactosidase and silicone rod coated with human thyroglobulin was developed for the measurement of circulating (anti-human thyroglobulin) autoantibody. The sensitivity of the assay with as little as 5 microliter of serum was 7 fmoles/tube corresponding to 220 ng/ml of serum, which was equal to or rather higher than that of radioimmunoassay. The highly significant correlation was observed between the concentrations of anti-thyroglobulin autoantibody determined by the present assay and a radioimmunoassay (r = 0.80, n = 74, p less than 0.001) and also between those by the present assay and those by tanned red cell hemagglutination (r = 0.78, n = 199, p less than 0.001). No effect of thyroglobulin on the present assay was observed unless the ratio of the amount of thyroglobulin to that of (anti-human thyroglobulin) immunoglobulin G was higher than a tenth.
Key concepts: Thyroglobulin, Radioimmunoassay, Autoantibody, Chemistry, Immunoassay, Antibody, Endocrinology, Internal medicine