1989PubMedRequires access

Quantitation of renal blood flow by contrast ultrasonography: preliminary results.

Paolo Voci, Paul A. Heidenreich, S Aronson, Wiencek Jg, Zaroff Jg, Feinstein Sb, A Reale

Open publisher page 13 citations

Abstract

Contrast ultrasonography, employing tracers behaving like red blood cells, is a promising technique to study regional blood flow distribution. Aim of this note is to quantitate renal blood flow in the dog using contrast ultrasonography. Mathematical formulae derived from the classical dye-dilution theory are applied. Ten different renal blood flow levels (ranging from 16 to 125 ml/min) were obtained by means of mechanical (stenosis and reperfusion) and pharmacological interventions (iv infusion of adrenaline, noradrenaline and fenoldopam). Renal blood flow was measured by electromagnetic flow-meter and contemporary calculated by contrast ultrasonography. The correlation coefficient between measured and calculated flow was 0.92 (p less than 0.01). Contrast ultrasonography is a technique capable of measuring renal blood flow at a wide range of different flow levels.

About this research paper

What this paper is about

Contrast ultrasonography, employing tracers behaving like red blood cells, is a promising technique to study regional blood flow distribution. Aim of this note is to quantitate renal blood flow in the dog using contrast ultrasonography. Mathematical formulae derived from the classical dye-dilution theory are applied. Ten different renal blood flow levels (ranging from 16 to 125 ml/min) were obtained by means of mechanical (stenosis and reperfusion) and pharmacological interventions (iv infusion of adrenaline, noradrenaline and fenoldopam). Renal blood flow was measured by electromagnetic flow-meter and contemporary calculated by contrast ultrasonography. The correlation coefficient between measured and calculated flow was 0.92 (p less than 0.01). Contrast ultrasonography is a technique capable of measuring renal blood flow at a wide range of different flow levels.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Contrast ultrasonography, employing tracers behaving like red blood cells, is a promising technique to study regional blood flow distribution. Aim of this note is to quantitate renal blood flow in the dog using contrast ultrasonography. Mathematical formulae derived from the classical dye-dilution theory are applied. Ten different renal blood flow levels (ranging from 16 to 125 ml/min) were obtained by means of mechanical (stenosis and reperfusion) and pharmacological interventions (iv infusion of adrenaline, noradrenaline and fenoldopam). Renal blood flow was measured by electromagnetic flow-meter and contemporary calculated by contrast ultrasonography. The correlation coefficient between measured and calculated flow was 0.92 (p less than 0.01). Contrast ultrasonography is a technique capable of measuring renal blood flow at a wide range of different flow levels.

Key concepts: Blood flow, Renal blood flow, Ultrasonography, Contrast (vision), Ultrasonic flow meter, Medicine, Kidney, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitation of renal blood flow by contrast ultrasonography: preliminary results. — Research Paper | ScholarLens