1997PubMedRequires access

[Fluorometric determination of trace Shachongdan with calcein-Pd2+].

Mou L, Yue Lu, C Zhang

Open publisher page 0 citations

Abstract

A fluorometric determination of trace Shachongdan (SCD) [(CH3)2NHCH (CH2S2O3- )CH2S2O3Na x H2O] is described. The method is based on the calcein display fluorescence in pH6-7 phosphate buffer solution, it react with Pd2+ to the fluorescence disappeared. The complex of SCD-Pd2+ is more stability than the complex of calcein-Pd2+, when SCD react with calcein -PdZ+, the calcein can be freed and its fluorescence appears once again. The fluorescence excitation and emission wavelenghts are 494 and 514nm. The linear range is 2 x 10(-7) mol/L-3 x 10(-6)mol/L and the detection limit is 6 x 10(-8)mol/L.

About this research paper

What this paper is about

A fluorometric determination of trace Shachongdan (SCD) [(CH3)2NHCH (CH2S2O3- )CH2S2O3Na x H2O] is described. The method is based on the calcein display fluorescence in pH6-7 phosphate buffer solution, it react with Pd2+ to the fluorescence disappeared. The complex of SCD-Pd2+ is more stability than the complex of calcein-Pd2+, when SCD react with calcein -PdZ+, the calcein can be freed and its fluorescence appears once again. The fluorescence excitation and emission wavelenghts are 494 and 514nm. The linear range is 2 x 10(-7) mol/L-3 x 10(-6)mol/L and the detection limit is 6 x 10(-8)mol/L.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fluorometric determination of trace Shachongdan (SCD) [(CH3)2NHCH (CH2S2O3- )CH2S2O3Na x H2O] is described. The method is based on the calcein display fluorescence in pH6-7 phosphate buffer solution, it react with Pd2+ to the fluorescence disappeared. The complex of SCD-Pd2+ is more stability than the complex of calcein-Pd2+, when SCD react with calcein -PdZ+, the calcein can be freed and its fluorescence appears once again. The fluorescence excitation and emission wavelenghts are 494 and 514nm. The linear range is 2 x 10(-7) mol/L-3 x 10(-6)mol/L and the detection limit is 6 x 10(-8)mol/L.

Key concepts: Calcein, Fluorescence, Detection limit, Chemistry, Linear range, Analytical Chemistry (journal), Chromatography, Membrane

Related papers

Back to paper searchBrowse research topicsOriginal source
[Fluorometric determination of trace Shachongdan with calcein-Pd2+]. — Research Paper | ScholarLens