2015대한건축학회 논문집 - 계획계Requires access

A Study on the Airflow Characteristics through the Entrance of Underground Parking Lots in Office Building

Byung-Hee Lee, Su-Whan Yee, Hyojin Kim, Dong-Hwa Kang, Myoung-Souk Yeo, Kwang-Woo Kim

Open publisher page 1 citations

Abstract

This paper shows the characteristics of airflow by infiltration through opening of underground parking lot in office building. This infiltration affects indoor air quality and building energy consumption. The effect of the wind velocity, direction and temperature differences between indoor and outdoor on the airflow through the building envelop has been investigated. In this study, the effect of the infiltration through opening of underground parking lot in office building will be analyzed using airflow network modeling by CONTAMW 3.0. Office building were simulated to confirm these characteristics. It is important to estimate the airflow and pressure difference across opening of underground parking lot for understanding the energy impacts of infiltration in office building because infiltration is likely to affect building energy consumption. As a result, there is general upward movement of air inside the building under outside cold conditions with airflow into vertical shafts from the lower floors and out to the upper ones. For preventing problems from the stack effect in office building, the first concern should be the improvement of airtightness in the opening of underground parking lot.

About this research paper

What this paper is about

This paper shows the characteristics of airflow by infiltration through opening of underground parking lot in office building. This infiltration affects indoor air quality and building energy consumption. The effect of the wind velocity, direction and temperature differences between indoor and outdoor on the airflow through the building envelop has been investigated. In this study, the effect of the infiltration through opening of underground parking lot in office building will be analyzed using airflow network modeling by CONTAMW 3.0. Office building were simulated to confirm these characteristics. It is important to estimate the airflow and pressure difference across opening of underground parking lot for understanding the energy impacts of infiltration in office building because infiltration is likely to affect building energy consumption. As a result, there is general upward movement of air inside the building under outside cold conditions with airflow into vertical shafts from the lower floors and out to the upper ones. For preventing problems from the stack effect in office building, the first concern should be the improvement of airtightness in the opening of underground parking lot.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper shows the characteristics of airflow by infiltration through opening of underground parking lot in office building. This infiltration affects indoor air quality and building energy consumption. The effect of the wind velocity, direction and temperature differences between indoor and outdoor on the airflow through the building envelop has been investigated. In this study, the effect of the infiltration through opening of underground parking lot in office building will be analyzed using airflow network modeling by CONTAMW 3.0. Office building were simulated to confirm these characteristics. It is important to estimate the airflow and pressure difference across opening of underground parking lot for understanding the energy impacts of infiltration in office building because infiltration is likely to affect building energy consumption. As a result, there is general upward movement of air inside the building under outside cold conditions with airflow into vertical shafts from the lower floors and out to the upper ones. For preventing problems from the stack effect in office building, the first concern should be the improvement of airtightness in the opening of underground parking lot.

Key concepts: Airflow, Infiltration (HVAC), Stack effect, Engineering, Indoor air quality, Parking lot, Environmental science, Energy consumption

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study on the Airflow Characteristics through the Entrance of Underground Parking Lots in Office Building — Research Paper | ScholarLens