2015International Journal of Energy for a Clean EnvironmentRequires access

HEAT TRANSFER ENHANCEMENT IN TURBULENT FLOW THROUGH A CIRCULAR TUBE WITH VARIOUS ARRANGEMENTS OF A DELTA WINGLET VORTEX GENERATOR

Md. Arif Mahmud Shuklo Shoshe, Rasel Ahmed, Mrinmoy Sarkar

Open publisher page 1 citations

Abstract

An experimental investigation was carried out to study heat transfer enhancement in turbulent flow through a circular tube with various arrangements of delta winglet vortex generator. Delta winglets of double row, double delta, and two pair 'V' array configurations were tested for their advantage over a single pair of delta winglet. For all configurations investigated, the projection area was 10.4% of the flow area. The test section was heated electrically at a constant wall heat flux. The frontal air velocity varied in the range from 5 m/s to 14 m/s corresponding the Reynolds number range based on the hydraulic diameter of 22,000 to 58,000. The air velocity, air inlet and outlet temperature, wall temperature, and pressure drops along the axial length of the test section were measured to analyze the friction factor, Nusselt number, and the heat transfer coefficient. Rearrangement of the projection area by these configurations of delta winglets provided a distinguishable increase in the Nusselt number and required lower pumping power. At comparable Reynolds numbers, using delta winglet vortex generators in two pair 'V' array, double delta, and double row configurations, the Nusselt number was increased up to 131.2%, 125.4%, and 118.4%, at 7%, 16%, and 15% less pumping power, respectively, compared to that of a single pair of delta winglet vortex generators.

About this research paper

What this paper is about

An experimental investigation was carried out to study heat transfer enhancement in turbulent flow through a circular tube with various arrangements of delta winglet vortex generator. Delta winglets of double row, double delta, and two pair 'V' array configurations were tested for their advantage over a single pair of delta winglet. For all configurations investigated, the projection area was 10.4% of the flow area. The test section was heated electrically at a constant wall heat flux. The frontal air velocity varied in the range from 5 m/s to 14 m/s corresponding the Reynolds number range based on the hydraulic diameter of 22,000 to 58,000. The air velocity, air inlet and outlet temperature, wall temperature, and pressure drops along the axial length of the test section were measured to analyze the friction factor, Nusselt number, and the heat transfer coefficient. Rearrangement of the projection area by these configurations of delta winglets provided a distinguishable increase in the Nusselt number and required lower pumping power. At comparable Reynolds numbers, using delta winglet vortex generators in two pair 'V' array, double delta, and double row configurations, the Nusselt number was increased up to 131.2%, 125.4%, and 118.4%, at 7%, 16%, and 15% less pumping power, respectively, compared to that of a single pair of delta winglet vortex generators.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An experimental investigation was carried out to study heat transfer enhancement in turbulent flow through a circular tube with various arrangements of delta winglet vortex generator. Delta winglets of double row, double delta, and two pair 'V' array configurations were tested for their advantage over a single pair of delta winglet. For all configurations investigated, the projection area was 10.4% of the flow area. The test section was heated electrically at a constant wall heat flux. The frontal air velocity varied in the range from 5 m/s to 14 m/s corresponding the Reynolds number range based on the hydraulic diameter of 22,000 to 58,000. The air velocity, air inlet and outlet temperature, wall temperature, and pressure drops along the axial length of the test section were measured to analyze the friction factor, Nusselt number, and the heat transfer coefficient. Rearrangement of the projection area by these configurations of delta winglets provided a distinguishable increase in the Nusselt number and required lower pumping power. At comparable Reynolds numbers, using delta winglet vortex generators in two pair 'V' array, double delta, and double row configurations, the Nusselt number was increased up to 131.2%, 125.4%, and 118.4%, at 7%, 16%, and 15% less pumping power, respectively, compared to that of a single pair of delta winglet vortex generators.

Key concepts: Nusselt number, Wingtip device, Vortex generator, Reynolds number, Turbulence, Mechanics, Heat transfer enhancement, Heat transfer

Related papers

Back to paper searchBrowse research topicsOriginal source
HEAT TRANSFER ENHANCEMENT IN TURBULENT FLOW THROUGH A CIRCULAR TUBE WITH VARIOUS ARRANGEMENTS OF A DELTA WINGLET VORTEX GENERATOR — Research Paper | ScholarLens