1994PubMedRequires access

Problems concerning the quality of DNA measurements on Feulgen-stained imprints. A study of five fixation techniques.

Michaela Aubele, G Burger, Karsten Rodenacker

Open publisher page 17 citations

Abstract

Feulgen-stained rat liver imprints were investigated, and hepatocytes, lymphocytes and granulocytes were measured. Additionally, chicken erythrocytes placed on the slides were measured as an external DNA standard. The imprints were treated according to five different fixation protocols. The measured integrated optical density (IOD) was normalized according to the leukocytes and afterwards scaled according to the diploid hepatocytes. The mean IOD, coefficient of variation (CV), standard error of the mean (SEM) and IOD ratios of distinct cell groups were calculated. The CV of the IOD for hepatocytes was slightly better for air-dried preparations. It was larger for leukocytes than for hepatocytes and worst for chicken erythrocytes. The SEM of hepatocytes did not show remarkable differences between the fixation groups; in general it was near 1%. In all cases the IOD ratios of 2c, 4c and 8c hepatocytes reasonably well followed the expected ratio of 1:2:4 except for wet, formalin-fixed hepatocytes (3.8). The ratios of leukocytes to 2c hepatocytes were about 1.0 for air-dried preparations but considerably lower (0.85) for wet fixation in formalin. The IOD ratios of chicken erythrocytes to 2C hepatocytes varied from 0.33 to 0.35. The deviation of the ratios of single specimens from the estimated mean of a fixation group are described.

About this research paper

What this paper is about

Feulgen-stained rat liver imprints were investigated, and hepatocytes, lymphocytes and granulocytes were measured. Additionally, chicken erythrocytes placed on the slides were measured as an external DNA standard. The imprints were treated according to five different fixation protocols. The measured integrated optical density (IOD) was normalized according to the leukocytes and afterwards scaled according to the diploid hepatocytes. The mean IOD, coefficient of variation (CV), standard error of the mean (SEM) and IOD ratios of distinct cell groups were calculated. The CV of the IOD for hepatocytes was slightly better for air-dried preparations. It was larger for leukocytes than for hepatocytes and worst for chicken erythrocytes. The SEM of hepatocytes did not show remarkable differences between the fixation groups; in general it was near 1%. In all cases the IOD ratios of 2c, 4c and 8c hepatocytes reasonably well followed the expected ratio of 1:2:4 except for wet, formalin-fixed hepatocytes (3.8). The ratios of leukocytes to 2c hepatocytes were about 1.0 for air-dried preparations but considerably lower (0.85) for wet fixation in formalin. The IOD ratios of chicken erythrocytes to 2C hepatocytes varied from 0.33 to 0.35. The deviation of the ratios of single specimens from the estimated mean of a fixation group are described.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Feulgen-stained rat liver imprints were investigated, and hepatocytes, lymphocytes and granulocytes were measured. Additionally, chicken erythrocytes placed on the slides were measured as an external DNA standard. The imprints were treated according to five different fixation protocols. The measured integrated optical density (IOD) was normalized according to the leukocytes and afterwards scaled according to the diploid hepatocytes. The mean IOD, coefficient of variation (CV), standard error of the mean (SEM) and IOD ratios of distinct cell groups were calculated. The CV of the IOD for hepatocytes was slightly better for air-dried preparations. It was larger for leukocytes than for hepatocytes and worst for chicken erythrocytes. The SEM of hepatocytes did not show remarkable differences between the fixation groups; in general it was near 1%. In all cases the IOD ratios of 2c, 4c and 8c hepatocytes reasonably well followed the expected ratio of 1:2:4 except for wet, formalin-fixed hepatocytes (3.8). The ratios of leukocytes to 2c hepatocytes were about 1.0 for air-dried preparations but considerably lower (0.85) for wet fixation in formalin. The IOD ratios of chicken erythrocytes to 2C hepatocytes varied from 0.33 to 0.35. The deviation of the ratios of single specimens from the estimated mean of a fixation group are described.

Key concepts: Feulgen stain, Fixation (population genetics), Coefficient of variation, Optical density, Ploidy, DNA, Chemistry, Molecular biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Problems concerning the quality of DNA measurements on Feulgen-stained imprints. A study of five fixation techniques. — Research Paper | ScholarLens