[Diagnostic value of 99mTc-methoxy-isobutyl-isonitril and 99mTc-methylene diphosphonate scintimammography in the preoperative evaluation of breast cancer].
Erzsébet Schmidt, K Kett, Béla Anga, József Bódis, Katalin Zámbó
Abstract
Erzsébet Schmidt, K Kett, Béla Anga, József Bódis, Katalin Zámbó
Abstract
AIM: To compare and establish the value of 99mTc-MIBI (methoxyisobutiylisonitrile) and 99mTc-MDP (methylene diphosphonate) scintigraphy in patients with suspicion of breast cancer. PATIENTS AND METHODS: The study included 105 patients. All patients were evaluated before surgery by 99mTc-MIBI and 99mTc-MDP scintigraphy. Thoracic SPECT study (Multispect II, Siemens) was performed 10 min. after i.v. injection of 99mTc-MIBI and 2 hours after i.v. injection of 99mTc-MDP. Final diagnosis was achieved after operation by histology. RESULTS: 99mTc-MIBI scintigraphy showed a better sensitivity (87%) than the 99mTc-MDP scintigraphy (81%) and the results are similar in specificity and validity, too. CONCLUSIONS: The results suggest that 99mTc-MIBI scintigraphy is a useful method in the preoperative diagnosis of patients with suspicion of breast cancer.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
AIM: To compare and establish the value of 99mTc-MIBI (methoxyisobutiylisonitrile) and 99mTc-MDP (methylene diphosphonate) scintigraphy in patients with suspicion of breast cancer. PATIENTS AND METHODS: The study included 105 patients. All patients were evaluated before surgery by 99mTc-MIBI and 99mTc-MDP scintigraphy. Thoracic SPECT study (Multispect II, Siemens) was performed 10 min. after i.v. injection of 99mTc-MIBI and 2 hours after i.v. injection of 99mTc-MDP. Final diagnosis was achieved after operation by histology. RESULTS: 99mTc-MIBI scintigraphy showed a better sensitivity (87%) than the 99mTc-MDP scintigraphy (81%) and the results are similar in specificity and validity, too. CONCLUSIONS: The results suggest that 99mTc-MIBI scintigraphy is a useful method in the preoperative diagnosis of patients with suspicion of breast cancer.
Key concepts: Scintimammography, Scintigraphy, Medicine, Breast cancer, Nuclear medicine, Radiology, Cancer, Mammography