2000•PubMedRequires access

Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect.

Tseng Hc, Po‐Ni Hsiao, Lin Yh, Jou‐Kou Wang, Tsai Sk

Open publisher page 12 citations

Abstract

BACKGROUND AND PURPOSE: Transcatheter closure of atrial septal defect (ASD) is generally performed under fluoroscopy alone. Recently, we have used transesophageal echocardiography (TEE) monitoring as an aid in performing this procedure. The purpose of this study was to evaluate the efficacy and complications associated with this use of TEE. METHODS: Transcatheter closure of ASD was accomplished under TEE guidance simultaneously with fluoroscopic imaging in 11 patients aged 3 to 33 years (weight, 15.4-62.9 kg). TEE was successfully performed in all patients after endotracheal general anesthesia. The ASDs were reexamined before catheterization. The appropriate placement of the occluder device was evaluated. RESULTS: Seven cases were uneventful with successful ASD occluder implantation, but one failed because of a large ASD (24.7 mm). In three cases, transcatheter closure was aborted after TEE examination, one with a large ASD (27.05 mm), one with an ASD that was too small, and one with multiple fenestrated ASDs. CONCLUSIONS: Routine TEE monitoring for transcatheter closure of ASDs is effective for evaluation of ASD before implantation of an occluder, to ensure the proper seating of the occluder after the defect occlusion is complete.

About this research paper

What this paper is about

BACKGROUND AND PURPOSE: Transcatheter closure of atrial septal defect (ASD) is generally performed under fluoroscopy alone. Recently, we have used transesophageal echocardiography (TEE) monitoring as an aid in performing this procedure. The purpose of this study was to evaluate the efficacy and complications associated with this use of TEE. METHODS: Transcatheter closure of ASD was accomplished under TEE guidance simultaneously with fluoroscopic imaging in 11 patients aged 3 to 33 years (weight, 15.4-62.9 kg). TEE was successfully performed in all patients after endotracheal general anesthesia. The ASDs were reexamined before catheterization. The appropriate placement of the occluder device was evaluated. RESULTS: Seven cases were uneventful with successful ASD occluder implantation, but one failed because of a large ASD (24.7 mm). In three cases, transcatheter closure was aborted after TEE examination, one with a large ASD (27.05 mm), one with an ASD that was too small, and one with multiple fenestrated ASDs. CONCLUSIONS: Routine TEE monitoring for transcatheter closure of ASDs is effective for evaluation of ASD before implantation of an occluder, to ensure the proper seating of the occluder after the defect occlusion is complete.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND PURPOSE: Transcatheter closure of atrial septal defect (ASD) is generally performed under fluoroscopy alone. Recently, we have used transesophageal echocardiography (TEE) monitoring as an aid in performing this procedure. The purpose of this study was to evaluate the efficacy and complications associated with this use of TEE. METHODS: Transcatheter closure of ASD was accomplished under TEE guidance simultaneously with fluoroscopic imaging in 11 patients aged 3 to 33 years (weight, 15.4-62.9 kg). TEE was successfully performed in all patients after endotracheal general anesthesia. The ASDs were reexamined before catheterization. The appropriate placement of the occluder device was evaluated. RESULTS: Seven cases were uneventful with successful ASD occluder implantation, but one failed because of a large ASD (24.7 mm). In three cases, transcatheter closure was aborted after TEE examination, one with a large ASD (27.05 mm), one with an ASD that was too small, and one with multiple fenestrated ASDs. CONCLUSIONS: Routine TEE monitoring for transcatheter closure of ASDs is effective for evaluation of ASD before implantation of an occluder, to ensure the proper seating of the occluder after the defect occlusion is complete.

Key concepts: Medicine, Fluoroscopy, Occlusion, Cardiac catheterization, Surgery, Radiology, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect. — Research Paper | ScholarLens