1989PubMedRequires access

[Esophago-jejunal anastomosis using an end-to-end anastomosis stapler. Clinico-radiologic study of early complications in 75 cases].

L Solaini, Aldo Campanini, P Ribichini, S Minguzzi, Isabelle Nanni, C Marri

Open publisher page 0 citations

Abstract

Personal experience with 75 consecutive cases of terminolaterale oesophagojejunal anastomosis by EEA Stapler is reported. A total of 6 intraoperative technical problems were encountered (8%) and consisted either of incomplete suturing of the anastomosis or stapling of the jejunal wall. Postoperative radiology revealed 5 dehiscences (6.6%) and 1 stenosis (1.33%). One patient with dehiscence died (1.33%) of septic complications. One dehiscence of the afferent jejunal stump and minor pleuropulmonary complications were observed in 3 cases. After a brief review of the literature, it is concluded that oesophagojejunal anastomosis by EEA Stapler produces a low incidence of postoperative complications such as the dehiscence, stenosis or bleeding.

About this research paper

What this paper is about

Personal experience with 75 consecutive cases of terminolaterale oesophagojejunal anastomosis by EEA Stapler is reported. A total of 6 intraoperative technical problems were encountered (8%) and consisted either of incomplete suturing of the anastomosis or stapling of the jejunal wall. Postoperative radiology revealed 5 dehiscences (6.6%) and 1 stenosis (1.33%). One patient with dehiscence died (1.33%) of septic complications. One dehiscence of the afferent jejunal stump and minor pleuropulmonary complications were observed in 3 cases. After a brief review of the literature, it is concluded that oesophagojejunal anastomosis by EEA Stapler produces a low incidence of postoperative complications such as the dehiscence, stenosis or bleeding.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Personal experience with 75 consecutive cases of terminolaterale oesophagojejunal anastomosis by EEA Stapler is reported. A total of 6 intraoperative technical problems were encountered (8%) and consisted either of incomplete suturing of the anastomosis or stapling of the jejunal wall. Postoperative radiology revealed 5 dehiscences (6.6%) and 1 stenosis (1.33%). One patient with dehiscence died (1.33%) of septic complications. One dehiscence of the afferent jejunal stump and minor pleuropulmonary complications were observed in 3 cases. After a brief review of the literature, it is concluded that oesophagojejunal anastomosis by EEA Stapler produces a low incidence of postoperative complications such as the dehiscence, stenosis or bleeding.

Key concepts: Medicine, Dehiscence, Anastomosis, Surgery, Stenosis, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Esophago-jejunal anastomosis using an end-to-end anastomosis stapler. Clinico-radiologic study of early complications in 75 cases]. — Research Paper | ScholarLens