1994PubMedRequires access

Pulmonary mechanics generated by positive end-expiratory and continuous negative pressure.

M Shoptaugh, Cvetnic Wg, Mikko Hallman, Feizal Waffarn, Jasper Stevens, T Blansfield, Michael Barsotti

Open publisher page 3 citations

Abstract

Pulmonary function measurements were studied on equivalent levels of positive end-expiratory pressure (PEEP) and continuous negative pressure (CNP) while controlling for transpulmonary pressure (TPP). Four adult rabbits were anesthetized, instrumented, and ventilated with intermittent mandatory ventilation by using peak inspiratory pressure (PIP) of 16 cm H2O, PEEP 0 cm H2O, CNP 0 cm H2O, inspiratory time 0.3 seconds, rate 20/min, and fraction of inspired oxygen of 0.3. Subsequently, equal amounts of PEEP and CNP were alternated for 15-minute ventilation periods. PIP was changed to approximate the TPP in each PEEP/CNP pair. There was a significant decrease in PCO2 and increase in pH, mechanical tidal volume, minute ventilation, functional residual capacity, and total dynamic compliance on CNP. These differences could not be explained by changes in TPP.

About this research paper

What this paper is about

Pulmonary function measurements were studied on equivalent levels of positive end-expiratory pressure (PEEP) and continuous negative pressure (CNP) while controlling for transpulmonary pressure (TPP). Four adult rabbits were anesthetized, instrumented, and ventilated with intermittent mandatory ventilation by using peak inspiratory pressure (PIP) of 16 cm H2O, PEEP 0 cm H2O, CNP 0 cm H2O, inspiratory time 0.3 seconds, rate 20/min, and fraction of inspired oxygen of 0.3. Subsequently, equal amounts of PEEP and CNP were alternated for 15-minute ventilation periods. PIP was changed to approximate the TPP in each PEEP/CNP pair. There was a significant decrease in PCO2 and increase in pH, mechanical tidal volume, minute ventilation, functional residual capacity, and total dynamic compliance on CNP. These differences could not be explained by changes in TPP.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pulmonary function measurements were studied on equivalent levels of positive end-expiratory pressure (PEEP) and continuous negative pressure (CNP) while controlling for transpulmonary pressure (TPP). Four adult rabbits were anesthetized, instrumented, and ventilated with intermittent mandatory ventilation by using peak inspiratory pressure (PIP) of 16 cm H2O, PEEP 0 cm H2O, CNP 0 cm H2O, inspiratory time 0.3 seconds, rate 20/min, and fraction of inspired oxygen of 0.3. Subsequently, equal amounts of PEEP and CNP were alternated for 15-minute ventilation periods. PIP was changed to approximate the TPP in each PEEP/CNP pair. There was a significant decrease in PCO2 and increase in pH, mechanical tidal volume, minute ventilation, functional residual capacity, and total dynamic compliance on CNP. These differences could not be explained by changes in TPP.

Key concepts: Transpulmonary pressure, Functional residual capacity, Medicine, Positive end-expiratory pressure, Tidal volume, Anesthesia, Ventilation (architecture), Peak inspiratory pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Pulmonary mechanics generated by positive end-expiratory and continuous negative pressure. — Research Paper | ScholarLens