Multicentric reference values: shared reference limits.

Montse Ferré-Masferrer, Xavier Fuentes‐Arderiu, Virtudes Álvarez-Funes, R. Güell-Miro, María José Castiñeiras-Lacambra

Open publisher page 20 citations

Abstract

In order to obtain shared reference limits, three laboratories in the same geographical area with a homogeneous population have developed a proposal to produce multicentric reference values. The strategy simulates a virtual laboratory, actually formed by the laboratories involved; the reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. Each laboratory has chosen its own reference sample and has measured the biochemical quantities under study. Reference individuals (n = 171) and 15 biochemical quantities among the most measured in clinical laboratories were selected. The reference values obtained in each laboratory were blended when permitted by the Harris & Boyd test (Clin Chem 1990; 36:265-70). The multicentric reference limits obtained by the virtual laboratory for each quantity were estimated according to the recommendations of the International Federation of Clinical Chemistry. For each quantity, each laboratory, with the results observed in their reference sample, estimated the diagnostic specificity, using as cut-off values the corresponding multicentric reference limits. Each observed value of diagnostic specificity was compared with the theoretical diagnostic specificity value, equal to 0.975, that should be observed when a reference limit is used as cut-off value. The multicentric reference limits obtained by the virtual laboratory are valid in all cases with the exception of the upper reference limit for the concentrations of calcium(II) and urate in serum in one of the laboratories.

About this research paper

What this paper is about

In order to obtain shared reference limits, three laboratories in the same geographical area with a homogeneous population have developed a proposal to produce multicentric reference values. The strategy simulates a virtual laboratory, actually formed by the laboratories involved; the reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. Each laboratory has chosen its own reference sample and has measured the biochemical quantities under study. Reference individuals (n = 171) and 15 biochemical quantities among the most measured in clinical laboratories were selected. The reference values obtained in each laboratory were blended when permitted by the Harris & Boyd test (Clin Chem 1990; 36:265-70). The multicentric reference limits obtained by the virtual laboratory for each quantity were estimated according to the recommendations of the International Federation of Clinical Chemistry. For each quantity, each laboratory, with the results observed in their reference sample, estimated the diagnostic specificity, using as cut-off values the corresponding multicentric reference limits. Each observed value of diagnostic specificity was compared with the theoretical diagnostic specificity value, equal to 0.975, that should be observed when a reference limit is used as cut-off value. The multicentric reference limits obtained by the virtual laboratory are valid in all cases with the exception of the upper reference limit for the concentrations of calcium(II) and urate in serum in one of the laboratories.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to obtain shared reference limits, three laboratories in the same geographical area with a homogeneous population have developed a proposal to produce multicentric reference values. The strategy simulates a virtual laboratory, actually formed by the laboratories involved; the reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. Each laboratory has chosen its own reference sample and has measured the biochemical quantities under study. Reference individuals (n = 171) and 15 biochemical quantities among the most measured in clinical laboratories were selected. The reference values obtained in each laboratory were blended when permitted by the Harris & Boyd test (Clin Chem 1990; 36:265-70). The multicentric reference limits obtained by the virtual laboratory for each quantity were estimated according to the recommendations of the International Federation of Clinical Chemistry. For each quantity, each laboratory, with the results observed in their reference sample, estimated the diagnostic specificity, using as cut-off values the corresponding multicentric reference limits. Each observed value of diagnostic specificity was compared with the theoretical diagnostic specificity value, equal to 0.975, that should be observed when a reference limit is used as cut-off value. The multicentric reference limits obtained by the virtual laboratory are valid in all cases with the exception of the upper reference limit for the concentrations of calcium(II) and urate in serum in one of the laboratories.

Key concepts: Reference values, Reference range, Reference data, Reference model, Sample (material), Population, Statistics, Reference genes

Related papers

Back to paper searchBrowse research topicsOriginal source
Multicentric reference values: shared reference limits. — Research Paper | ScholarLens