1999PubMedRequires access

Evaluation of renal function from 99mTc-MAG3 renography without blood sampling.

Yusuke Inoue, Tohru Ohtake, Ikuo Yokoyama, Kohki Yoshikawa, Sae Asai, Kuni Ohtomo

Open publisher page 21 citations

Abstract

UNLABELLED: To develop a camera-based method for evaluating renal function with 99mTc-mercaptoacetyltriglycine (MAG3), we examined the relationship between various renogram parameters and 99mTc-MAG3 clearance. METHODS: Twenty-one patients underwent renal scintigraphy with 99mTc-MAG3. Eighty 3-s frames were obtained after the bolus injection of 250 MBq tracer, followed by the collection of 52 30-s frames. Regions of interest were drawn for the kidneys, perirenal background areas and subrenal background areas, and background-subtracted renograms were generated. Renal accumulation at 0.5-1.5, 0.5-2, 1-2, 1-2.5 and 1.5-2.5 min after tracer arrival in the kidney was calculated as area under the background-subtracted renogram, and percent renal uptake was obtained after correction for soft-tissue attenuation and injected dose. The slope of the renogram was determined for the same segments used in calculating area under the renogram, and slope index was computed as slope corrected for attenuation and injected dose. Percent renal uptakes and slope indices were correlated by linear regression analysis with 99mTc-MAG3 clearance measured using a single blood sampling method. RESULTS: Among the values of percent renal uptake, the value obtained at 1.5-2.5 min using the perirenal background correlated best with 99mTc-MAG3 clearance. The slope index at 0.5-1.5 or 0.5-2 min using the subrenal background provided better accuracy than percent renal uptake for predicting clearance. There were no substantial differences in the relative function of the right kidney between the methods using percent renal uptake and slope index. CONCLUSION: 99mTc-MAG3 clearance can be assessed with acceptable accuracy by a camera-based method. The method based on the slope of the renogram may replace the one based on the area under the renogram in evaluating renal function from 99mTc-MAG3 renograms.

About this research paper

What this paper is about

UNLABELLED: To develop a camera-based method for evaluating renal function with 99mTc-mercaptoacetyltriglycine (MAG3), we examined the relationship between various renogram parameters and 99mTc-MAG3 clearance. METHODS: Twenty-one patients underwent renal scintigraphy with 99mTc-MAG3. Eighty 3-s frames were obtained after the bolus injection of 250 MBq tracer, followed by the collection of 52 30-s frames. Regions of interest were drawn for the kidneys, perirenal background areas and subrenal background areas, and background-subtracted renograms were generated. Renal accumulation at 0.5-1.5, 0.5-2, 1-2, 1-2.5 and 1.5-2.5 min after tracer arrival in the kidney was calculated as area under the background-subtracted renogram, and percent renal uptake was obtained after correction for soft-tissue attenuation and injected dose. The slope of the renogram was determined for the same segments used in calculating area under the renogram, and slope index was computed as slope corrected for attenuation and injected dose. Percent renal uptakes and slope indices were correlated by linear regression analysis with 99mTc-MAG3 clearance measured using a single blood sampling method. RESULTS: Among the values of percent renal uptake, the value obtained at 1.5-2.5 min using the perirenal background correlated best with 99mTc-MAG3 clearance. The slope index at 0.5-1.5 or 0.5-2 min using the subrenal background provided better accuracy than percent renal uptake for predicting clearance. There were no substantial differences in the relative function of the right kidney between the methods using percent renal uptake and slope index. CONCLUSION: 99mTc-MAG3 clearance can be assessed with acceptable accuracy by a camera-based method. The method based on the slope of the renogram may replace the one based on the area under the renogram in evaluating renal function from 99mTc-MAG3 renograms.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: To develop a camera-based method for evaluating renal function with 99mTc-mercaptoacetyltriglycine (MAG3), we examined the relationship between various renogram parameters and 99mTc-MAG3 clearance. METHODS: Twenty-one patients underwent renal scintigraphy with 99mTc-MAG3. Eighty 3-s frames were obtained after the bolus injection of 250 MBq tracer, followed by the collection of 52 30-s frames. Regions of interest were drawn for the kidneys, perirenal background areas and subrenal background areas, and background-subtracted renograms were generated. Renal accumulation at 0.5-1.5, 0.5-2, 1-2, 1-2.5 and 1.5-2.5 min after tracer arrival in the kidney was calculated as area under the background-subtracted renogram, and percent renal uptake was obtained after correction for soft-tissue attenuation and injected dose. The slope of the renogram was determined for the same segments used in calculating area under the renogram, and slope index was computed as slope corrected for attenuation and injected dose. Percent renal uptakes and slope indices were correlated by linear regression analysis with 99mTc-MAG3 clearance measured using a single blood sampling method. RESULTS: Among the values of percent renal uptake, the value obtained at 1.5-2.5 min using the perirenal background correlated best with 99mTc-MAG3 clearance. The slope index at 0.5-1.5 or 0.5-2 min using the subrenal background provided better accuracy than percent renal uptake for predicting clearance. There were no substantial differences in the relative function of the right kidney between the methods using percent renal uptake and slope index. CONCLUSION: 99mTc-MAG3 clearance can be assessed with acceptable accuracy by a camera-based method. The method based on the slope of the renogram may replace the one based on the area under the renogram in evaluating renal function from 99mTc-MAG3 renograms.

Key concepts: Renal function, Nuclear medicine, Medicine, Kidney, Scintigraphy, Technetium, Urology, Bolus (digestion)

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of renal function from 99mTc-MAG3 renography without blood sampling. — Research Paper | ScholarLens