2016The LaryngoscopeRequires access

The effect of bolus consistency on swallowing function measured by high‐resolution manometry in healthy volunteers

Yue Lan, Guangqing Xu, Fan Yu, Tuo Lin, Li‐sheng Jiang, Feng Liu

Open publisher page 16 citations

Abstract

OBJECTIVES/HYPOTHESIS: This study evaluated the effects of three levels of bolus consistency (water, thick liquid, and paste) on the nature and duration of physiologic pressure while swallowing in healthy adults using high-resolution manometry (HRM). STUDY DESIGN: A case series of healthy adults. METHODS: Thirty-four healthy young adults (mean age: 24.29 years) were instructed to swallow 3 mL and 10 mL of water, thick liquid, and paste material, respectively, during which the upper esophageal sphincter (UES) and pharyngeal pressures were measured by HRM. Variables that included maximum pharyngeal pressure, duration of pharyngeal pressure, pharyngeal pressure rise rate, UES residual pressure, duration of UES relaxation, and maximum preopening as well as postclosure UES pressure were analyzed across the three bolus consistencies by one-way repeated measures analysis of variance. RESULTS: Maximum pharyngeal pressure, duration of pharyngeal pressure, duration of UES relaxation, maximum preopening UES pressure, and maximum postclosure UES pressure were significantly increased while swallowing water when compared with the thick liquid and paste materials. No significant differences were observed in UES residual pressure and pharyngeal pressure rise rate among the three different consistencies. CONCLUSION: Variations in bolus consistency appear to have a significant effect on physiologic pressure and duration in healthy adults while swallowing water when compared with thicker materials. Identification of the differences across various bolus consistencies could provide further insight into the pathophysiology of both normal and pathological swallowing. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:173-178, 2017.

About this research paper

What this paper is about

OBJECTIVES/HYPOTHESIS: This study evaluated the effects of three levels of bolus consistency (water, thick liquid, and paste) on the nature and duration of physiologic pressure while swallowing in healthy adults using high-resolution manometry (HRM). STUDY DESIGN: A case series of healthy adults. METHODS: Thirty-four healthy young adults (mean age: 24.29 years) were instructed to swallow 3 mL and 10 mL of water, thick liquid, and paste material, respectively, during which the upper esophageal sphincter (UES) and pharyngeal pressures were measured by HRM. Variables that included maximum pharyngeal pressure, duration of pharyngeal pressure, pharyngeal pressure rise rate, UES residual pressure, duration of UES relaxation, and maximum preopening as well as postclosure UES pressure were analyzed across the three bolus consistencies by one-way repeated measures analysis of variance. RESULTS: Maximum pharyngeal pressure, duration of pharyngeal pressure, duration of UES relaxation, maximum preopening UES pressure, and maximum postclosure UES pressure were significantly increased while swallowing water when compared with the thick liquid and paste materials. No significant differences were observed in UES residual pressure and pharyngeal pressure rise rate among the three different consistencies. CONCLUSION: Variations in bolus consistency appear to have a significant effect on physiologic pressure and duration in healthy adults while swallowing water when compared with thicker materials. Identification of the differences across various bolus consistencies could provide further insight into the pathophysiology of both normal and pathological swallowing. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:173-178, 2017.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES/HYPOTHESIS: This study evaluated the effects of three levels of bolus consistency (water, thick liquid, and paste) on the nature and duration of physiologic pressure while swallowing in healthy adults using high-resolution manometry (HRM). STUDY DESIGN: A case series of healthy adults. METHODS: Thirty-four healthy young adults (mean age: 24.29 years) were instructed to swallow 3 mL and 10 mL of water, thick liquid, and paste material, respectively, during which the upper esophageal sphincter (UES) and pharyngeal pressures were measured by HRM. Variables that included maximum pharyngeal pressure, duration of pharyngeal pressure, pharyngeal pressure rise rate, UES residual pressure, duration of UES relaxation, and maximum preopening as well as postclosure UES pressure were analyzed across the three bolus consistencies by one-way repeated measures analysis of variance. RESULTS: Maximum pharyngeal pressure, duration of pharyngeal pressure, duration of UES relaxation, maximum preopening UES pressure, and maximum postclosure UES pressure were significantly increased while swallowing water when compared with the thick liquid and paste materials. No significant differences were observed in UES residual pressure and pharyngeal pressure rise rate among the three different consistencies. CONCLUSION: Variations in bolus consistency appear to have a significant effect on physiologic pressure and duration in healthy adults while swallowing water when compared with thicker materials. Identification of the differences across various bolus consistencies could provide further insight into the pathophysiology of both normal and pathological swallowing. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:173-178, 2017.

Key concepts: Swallowing, High resolution manometry, Bolus (digestion), Medicine, Anesthesia, Pharynx, Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of bolus consistency on swallowing function measured by high‐resolution manometry in healthy volunteers — Research Paper | ScholarLens