1988•PubMedRequires access

[Study on splanchnic circulation: measurement of the liver blood flow].

Ryuichiro Doi, Kazuhide Inoue, Masafumi Kogire, S Sumi, Kyoichi Takaori, Takahiro Suzuki, Takayoshi Tobe

Open publisher page 1 citations

Abstract

In anesthetized patients during abdominal surgery, hepatic artery and portal vein flows were measured simultaneously utilizing an ultrasonic transit-time volume flowmeter. The total hepatic blood flow was 994.6 +/- 52.4 ml/min. The hepatic artery flow and the portal vein flow were 260.0 +/- 23.8 ml/min and 730.8 +/- 41.3 ml/min, respectively. The ratio of hepatic artery flow to portal vein flow was 0.37 +/- 0.04. A significant increase in hepatic artery flow (p less than 0.01) followed portal vein occlusion, whereas no significant change was observed in portal vein flow after hepatic artery occlusion. Common hepatic artery occlusion resulted in a significant decrease in hepatic artery flow (p less than 0.05), but no significant change was observed in portal vein flow. The present study firstly demonstrated that ultrasonic transit-time volume flowmeter is a device to quantitatively assess hepatic artery and portal vein flows with good reproducibility and stability in human subjects. This easy and simple technique seemed to have wide clinical application to abdominal surgery and would have a promising in studying splanchnic blood flows in various situations such as in cases of hepatectomy and portal hypertension.

About this research paper

What this paper is about

In anesthetized patients during abdominal surgery, hepatic artery and portal vein flows were measured simultaneously utilizing an ultrasonic transit-time volume flowmeter. The total hepatic blood flow was 994.6 +/- 52.4 ml/min. The hepatic artery flow and the portal vein flow were 260.0 +/- 23.8 ml/min and 730.8 +/- 41.3 ml/min, respectively. The ratio of hepatic artery flow to portal vein flow was 0.37 +/- 0.04. A significant increase in hepatic artery flow (p less than 0.01) followed portal vein occlusion, whereas no significant change was observed in portal vein flow after hepatic artery occlusion. Common hepatic artery occlusion resulted in a significant decrease in hepatic artery flow (p less than 0.05), but no significant change was observed in portal vein flow. The present study firstly demonstrated that ultrasonic transit-time volume flowmeter is a device to quantitatively assess hepatic artery and portal vein flows with good reproducibility and stability in human subjects. This easy and simple technique seemed to have wide clinical application to abdominal surgery and would have a promising in studying splanchnic blood flows in various situations such as in cases of hepatectomy and portal hypertension.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In anesthetized patients during abdominal surgery, hepatic artery and portal vein flows were measured simultaneously utilizing an ultrasonic transit-time volume flowmeter. The total hepatic blood flow was 994.6 +/- 52.4 ml/min. The hepatic artery flow and the portal vein flow were 260.0 +/- 23.8 ml/min and 730.8 +/- 41.3 ml/min, respectively. The ratio of hepatic artery flow to portal vein flow was 0.37 +/- 0.04. A significant increase in hepatic artery flow (p less than 0.01) followed portal vein occlusion, whereas no significant change was observed in portal vein flow after hepatic artery occlusion. Common hepatic artery occlusion resulted in a significant decrease in hepatic artery flow (p less than 0.05), but no significant change was observed in portal vein flow. The present study firstly demonstrated that ultrasonic transit-time volume flowmeter is a device to quantitatively assess hepatic artery and portal vein flows with good reproducibility and stability in human subjects. This easy and simple technique seemed to have wide clinical application to abdominal surgery and would have a promising in studying splanchnic blood flows in various situations such as in cases of hepatectomy and portal hypertension.

Key concepts: Medicine, Splanchnic Circulation, Splanchnic, Artery, Blood flow, Common hepatic artery, Occlusion, Right gastric vein

Related papers

Back to paper searchBrowse research topicsOriginal source
[Study on splanchnic circulation: measurement of the liver blood flow]. — Research Paper | ScholarLens