In vitroevaluation of the accuracy of ProPex II, Raypex 6 and iPex II electronic apex locators in primary molar teeth
Levent Demiriz, MustafaMurat Koçak, BaranCan Sağlam, Sibel Koçak
Abstract
Levent Demiriz, MustafaMurat Koçak, BaranCan Sağlam, Sibel Koçak
Abstract
Background: Electronic apex locators (EALs) have become popular to measure the working length in permanent teeth in recent years, and they have helped for estimation of the working length more accurate. Objective: The purpose of this study is to evaluate the accuracy of ProPex II, Raypex 6 and iPex II EALs in primary molar teeth. Materials and Methods: Fifteen mandibular primary second molar teeth with 48 root canals were measured by all EALs. The direct length (DL) of the root canals was measured visually. The differences between DL and electronic working length (EWL) measurements of each device were calculated. Statistically analysis was performed using Student's t-test, and the significance level was at 5%. Results: For the measurements of ProPex II, the reliability of ±0.5 mm was determined in 77% of all root canals. For Raypex 6, the same result (77%) was observed when the accuracy was also accepted as ±0.5 mm. On the other hand, the result was found as 79% in the measurements of iPex II when the same accuracy limit (±0.5 mm) was considered. When the accuracy limit was ±1 mm, the determined values were 96% for ProPex II and Raypex 6 and 94% for iPex II. There was no significant difference between each EAL group (P > 0.05). Conclusion: The ProPex II, Raypex 6, and iPex II EALs showed similar results and all tested EALs were able to determine the working length in primary molar teeth accurately.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: Electronic apex locators (EALs) have become popular to measure the working length in permanent teeth in recent years, and they have helped for estimation of the working length more accurate. Objective: The purpose of this study is to evaluate the accuracy of ProPex II, Raypex 6 and iPex II EALs in primary molar teeth. Materials and Methods: Fifteen mandibular primary second molar teeth with 48 root canals were measured by all EALs. The direct length (DL) of the root canals was measured visually. The differences between DL and electronic working length (EWL) measurements of each device were calculated. Statistically analysis was performed using Student's t-test, and the significance level was at 5%. Results: For the measurements of ProPex II, the reliability of ±0.5 mm was determined in 77% of all root canals. For Raypex 6, the same result (77%) was observed when the accuracy was also accepted as ±0.5 mm. On the other hand, the result was found as 79% in the measurements of iPex II when the same accuracy limit (±0.5 mm) was considered. When the accuracy limit was ±1 mm, the determined values were 96% for ProPex II and Raypex 6 and 94% for iPex II. There was no significant difference between each EAL group (P > 0.05). Conclusion: The ProPex II, Raypex 6, and iPex II EALs showed similar results and all tested EALs were able to determine the working length in primary molar teeth accurately.
Key concepts: Apex (geometry), Molar, Mathematics, Orthodontics, Dentistry, Limits of agreement, Medicine, Nuclear medicine