In vitroevaluation of the accuracy of ProPex II, Raypex 6 and iPex II electronic apex locators in primary molar teeth

Levent Demiriz, MustafaMurat Koçak, BaranCan Sağlam, Sibel Koçak

Open full text 5 citations

Abstract

Background: Electronic apex locators (EALs) have become popular to measure the working length in permanent teeth in recent years, and they have helped for estimation of the working length more accurate. Objective: The purpose of this study is to evaluate the accuracy of ProPex II, Raypex 6 and iPex II EALs in primary molar teeth. Materials and Methods: Fifteen mandibular primary second molar teeth with 48 root canals were measured by all EALs. The direct length (DL) of the root canals was measured visually. The differences between DL and electronic working length (EWL) measurements of each device were calculated. Statistically analysis was performed using Student's t-test, and the significance level was at 5%. Results: For the measurements of ProPex II, the reliability of ±0.5 mm was determined in 77% of all root canals. For Raypex 6, the same result (77%) was observed when the accuracy was also accepted as ±0.5 mm. On the other hand, the result was found as 79% in the measurements of iPex II when the same accuracy limit (±0.5 mm) was considered. When the accuracy limit was ±1 mm, the determined values were 96% for ProPex II and Raypex 6 and 94% for iPex II. There was no significant difference between each EAL group (P > 0.05). Conclusion: The ProPex II, Raypex 6, and iPex II EALs showed similar results and all tested EALs were able to determine the working length in primary molar teeth accurately.

About this research paper

What this paper is about

Background: Electronic apex locators (EALs) have become popular to measure the working length in permanent teeth in recent years, and they have helped for estimation of the working length more accurate. Objective: The purpose of this study is to evaluate the accuracy of ProPex II, Raypex 6 and iPex II EALs in primary molar teeth. Materials and Methods: Fifteen mandibular primary second molar teeth with 48 root canals were measured by all EALs. The direct length (DL) of the root canals was measured visually. The differences between DL and electronic working length (EWL) measurements of each device were calculated. Statistically analysis was performed using Student's t-test, and the significance level was at 5%. Results: For the measurements of ProPex II, the reliability of ±0.5 mm was determined in 77% of all root canals. For Raypex 6, the same result (77%) was observed when the accuracy was also accepted as ±0.5 mm. On the other hand, the result was found as 79% in the measurements of iPex II when the same accuracy limit (±0.5 mm) was considered. When the accuracy limit was ±1 mm, the determined values were 96% for ProPex II and Raypex 6 and 94% for iPex II. There was no significant difference between each EAL group (P > 0.05). Conclusion: The ProPex II, Raypex 6, and iPex II EALs showed similar results and all tested EALs were able to determine the working length in primary molar teeth accurately.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Electronic apex locators (EALs) have become popular to measure the working length in permanent teeth in recent years, and they have helped for estimation of the working length more accurate. Objective: The purpose of this study is to evaluate the accuracy of ProPex II, Raypex 6 and iPex II EALs in primary molar teeth. Materials and Methods: Fifteen mandibular primary second molar teeth with 48 root canals were measured by all EALs. The direct length (DL) of the root canals was measured visually. The differences between DL and electronic working length (EWL) measurements of each device were calculated. Statistically analysis was performed using Student's t-test, and the significance level was at 5%. Results: For the measurements of ProPex II, the reliability of ±0.5 mm was determined in 77% of all root canals. For Raypex 6, the same result (77%) was observed when the accuracy was also accepted as ±0.5 mm. On the other hand, the result was found as 79% in the measurements of iPex II when the same accuracy limit (±0.5 mm) was considered. When the accuracy limit was ±1 mm, the determined values were 96% for ProPex II and Raypex 6 and 94% for iPex II. There was no significant difference between each EAL group (P > 0.05). Conclusion: The ProPex II, Raypex 6, and iPex II EALs showed similar results and all tested EALs were able to determine the working length in primary molar teeth accurately.

Key concepts: Apex (geometry), Molar, Mathematics, Orthodontics, Dentistry, Limits of agreement, Medicine, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
In vitroevaluation of the accuracy of ProPex II, Raypex 6 and iPex II electronic apex locators in primary molar teeth — Research Paper | ScholarLens