2012•PubMedRequires access

[The improvement of determination method of carbon disulfide in workplace air with gas chromatography].

Qing-feng Xiao, Wenhua Qin, Yanyan Lu, Shanfa Yu

Open publisher page 0 citations

Abstract

OBJECTIVE: Establishment of determination method of carbon disulfide in charcoal tube with low toxicity solvents desorption-gas chromatography. METHODS: Four types of solvent with low toxicity are applied respectively as substitution of benzene to desorb the carbon disulfide in samples of charcoal tube. The signal strength and desorption efficiency of the detector are compared by using different solvents. RESULTS: Chloroform has been considered as the best alternative solvent of benzene. Carbon disulfide has a good linearity (R = 0.9997) over the concentration of 0 ∼ 54.7 µg/ml, detection limit can reach 0.2 µg/ml. When the sampling volume is 3.0 L, the minimum detectable concentration is 0.07 mg/m(3). CONCLUSION: With the use of chloroform, the health hazard to laboratory personnel and environment pollution as well as the costs of experiments are reduced.

About this research paper

What this paper is about

OBJECTIVE: Establishment of determination method of carbon disulfide in charcoal tube with low toxicity solvents desorption-gas chromatography. METHODS: Four types of solvent with low toxicity are applied respectively as substitution of benzene to desorb the carbon disulfide in samples of charcoal tube. The signal strength and desorption efficiency of the detector are compared by using different solvents. RESULTS: Chloroform has been considered as the best alternative solvent of benzene. Carbon disulfide has a good linearity (R = 0.9997) over the concentration of 0 ∼ 54.7 µg/ml, detection limit can reach 0.2 µg/ml. When the sampling volume is 3.0 L, the minimum detectable concentration is 0.07 mg/m(3). CONCLUSION: With the use of chloroform, the health hazard to laboratory personnel and environment pollution as well as the costs of experiments are reduced.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Establishment of determination method of carbon disulfide in charcoal tube with low toxicity solvents desorption-gas chromatography. METHODS: Four types of solvent with low toxicity are applied respectively as substitution of benzene to desorb the carbon disulfide in samples of charcoal tube. The signal strength and desorption efficiency of the detector are compared by using different solvents. RESULTS: Chloroform has been considered as the best alternative solvent of benzene. Carbon disulfide has a good linearity (R = 0.9997) over the concentration of 0 ∼ 54.7 µg/ml, detection limit can reach 0.2 µg/ml. When the sampling volume is 3.0 L, the minimum detectable concentration is 0.07 mg/m(3). CONCLUSION: With the use of chloroform, the health hazard to laboratory personnel and environment pollution as well as the costs of experiments are reduced.

Key concepts: Carbon disulfide, Chemistry, Detection limit, Charcoal, Solvent, Chloroform, Gas chromatography, Benzene

Related papers

Back to paper searchBrowse research topicsOriginal source
[The improvement of determination method of carbon disulfide in workplace air with gas chromatography]. — Research Paper | ScholarLens