1999PubMedRequires access

[Intensity-modulation radiotherapy using independent collimator: algorithm study].

Jianrong Dai, Hu Yudong

Open publisher page 0 citations

Abstract

To investigate algorithms for independent collimator (IC) to modulate beam intensity distributions. Field-setting sequences were determined for three clinical intensity distributions with two forward algorithms. The delivery order of all fields in the sequences was optimized in order to minimize the overall jaw-moving time. Suppose treatments were performed with Varian 600C, delivery time was calculated. The delivery time was between 5 min to 10 min, It was approximately inversely proportional to machine dose rate, and also related to algorithm, number of intensity levels and metrix element size.

About this research paper

What this paper is about

To investigate algorithms for independent collimator (IC) to modulate beam intensity distributions. Field-setting sequences were determined for three clinical intensity distributions with two forward algorithms. The delivery order of all fields in the sequences was optimized in order to minimize the overall jaw-moving time. Suppose treatments were performed with Varian 600C, delivery time was calculated. The delivery time was between 5 min to 10 min, It was approximately inversely proportional to machine dose rate, and also related to algorithm, number of intensity levels and metrix element size.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To investigate algorithms for independent collimator (IC) to modulate beam intensity distributions. Field-setting sequences were determined for three clinical intensity distributions with two forward algorithms. The delivery order of all fields in the sequences was optimized in order to minimize the overall jaw-moving time. Suppose treatments were performed with Varian 600C, delivery time was calculated. The delivery time was between 5 min to 10 min, It was approximately inversely proportional to machine dose rate, and also related to algorithm, number of intensity levels and metrix element size.

Key concepts: Collimator, Intensity modulation, Intensity (physics), Multileaf collimator, Algorithm, Modulation (music), Mathematics, Radiant intensity

Related papers

Back to paper searchBrowse research topicsOriginal source
[Intensity-modulation radiotherapy using independent collimator: algorithm study]. — Research Paper | ScholarLens