2015PubMedRequires access

[Value of IL-6 and IL-8 in the diagnosis of neonatal sepsis].

Feng-Xia Zhao, Guanghui Liu, Jian Zhang

Open publisher page 11 citations

Abstract

OBJECTIVE: To explore the significance of interleukin-6 (IL-6) and IL-8 in the diagnosis of neonatal sepsis. METHODS: This was a prospective study conducted between August 2014 and February 2015. A total of 140 neonates who were suspected infectious were enrolled and classified into a sepsis group (n=49) and a local infection group (n=91). Sixty-one neonates who were non-infectious served as the control group. Serum levels of IL-6 and IL-8 were measured before treatment and 3 days after treatment. The value of serum IL-6 and IL-8 for the diagnosis of neonatal sepsis was assessed by receiver operating characteristic (ROC) curve analysis. RESULTS: Before treatment, serum levels of IL-6 and IL-8 in the sepsis group were higher than those in the local infection and control groups (P<0.05), and the local infection group had higher serum levels of IL-6 and IL-8 than the control group (P<0.05). After three days of treatment, the serum IL-6 level in the sepsis group remained higher than that in the local infection and control groups (P<0.05), and the local infection group had higher serum level of IL-6 than the control group (P<0.05). There was no significant difference in the serum IL-8 level among the three groups. According to the ROC curve, when the cut-off value of serum IL-6 was 32 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 87.8%, 79.6% and 81.6% respectively; when the cut-off value of serum IL-8 was 54 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 77.6%, 63.8% and 67.2% respectively. With the combination of serum IL-6 and IL-8 levels, the sensitivity, specificity and accuracy for the diagnosis of neonatal sepsis were 71.4%, 86.2% and 82.6% respectively. CONCLUSIONS: IL-6 and IL-8 participate in the inflammatory response and the serum levels of both vary with the severity of infection. The diagnostic value of IL-6 for neonatal sepsis is higher than IL-8. The combined detection of serum levels IL-6 and IL-8 may increase the accuracy of diagnosis of neonatal sepsis.

About this research paper

What this paper is about

OBJECTIVE: To explore the significance of interleukin-6 (IL-6) and IL-8 in the diagnosis of neonatal sepsis. METHODS: This was a prospective study conducted between August 2014 and February 2015. A total of 140 neonates who were suspected infectious were enrolled and classified into a sepsis group (n=49) and a local infection group (n=91). Sixty-one neonates who were non-infectious served as the control group. Serum levels of IL-6 and IL-8 were measured before treatment and 3 days after treatment. The value of serum IL-6 and IL-8 for the diagnosis of neonatal sepsis was assessed by receiver operating characteristic (ROC) curve analysis. RESULTS: Before treatment, serum levels of IL-6 and IL-8 in the sepsis group were higher than those in the local infection and control groups (P<0.05), and the local infection group had higher serum levels of IL-6 and IL-8 than the control group (P<0.05). After three days of treatment, the serum IL-6 level in the sepsis group remained higher than that in the local infection and control groups (P<0.05), and the local infection group had higher serum level of IL-6 than the control group (P<0.05). There was no significant difference in the serum IL-8 level among the three groups. According to the ROC curve, when the cut-off value of serum IL-6 was 32 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 87.8%, 79.6% and 81.6% respectively; when the cut-off value of serum IL-8 was 54 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 77.6%, 63.8% and 67.2% respectively. With the combination of serum IL-6 and IL-8 levels, the sensitivity, specificity and accuracy for the diagnosis of neonatal sepsis were 71.4%, 86.2% and 82.6% respectively. CONCLUSIONS: IL-6 and IL-8 participate in the inflammatory response and the serum levels of both vary with the severity of infection. The diagnostic value of IL-6 for neonatal sepsis is higher than IL-8. The combined detection of serum levels IL-6 and IL-8 may increase the accuracy of diagnosis of neonatal sepsis.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To explore the significance of interleukin-6 (IL-6) and IL-8 in the diagnosis of neonatal sepsis. METHODS: This was a prospective study conducted between August 2014 and February 2015. A total of 140 neonates who were suspected infectious were enrolled and classified into a sepsis group (n=49) and a local infection group (n=91). Sixty-one neonates who were non-infectious served as the control group. Serum levels of IL-6 and IL-8 were measured before treatment and 3 days after treatment. The value of serum IL-6 and IL-8 for the diagnosis of neonatal sepsis was assessed by receiver operating characteristic (ROC) curve analysis. RESULTS: Before treatment, serum levels of IL-6 and IL-8 in the sepsis group were higher than those in the local infection and control groups (P<0.05), and the local infection group had higher serum levels of IL-6 and IL-8 than the control group (P<0.05). After three days of treatment, the serum IL-6 level in the sepsis group remained higher than that in the local infection and control groups (P<0.05), and the local infection group had higher serum level of IL-6 than the control group (P<0.05). There was no significant difference in the serum IL-8 level among the three groups. According to the ROC curve, when the cut-off value of serum IL-6 was 32 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 87.8%, 79.6% and 81.6% respectively; when the cut-off value of serum IL-8 was 54 pg/mL, the sensitivity, specificity and accuracy of serum IL-6 for the diagnosis of neonatal sepsis were 77.6%, 63.8% and 67.2% respectively. With the combination of serum IL-6 and IL-8 levels, the sensitivity, specificity and accuracy for the diagnosis of neonatal sepsis were 71.4%, 86.2% and 82.6% respectively. CONCLUSIONS: IL-6 and IL-8 participate in the inflammatory response and the serum levels of both vary with the severity of infection. The diagnostic value of IL-6 for neonatal sepsis is higher than IL-8. The combined detection of serum levels IL-6 and IL-8 may increase the accuracy of diagnosis of neonatal sepsis.

Key concepts: Sepsis, Neonatal sepsis, Medicine, Gastroenterology, Receiver operating characteristic, Internal medicine, Interleukin 10, Interleukin 6

Related papers

Back to paper searchBrowse research topicsOriginal source
[Value of IL-6 and IL-8 in the diagnosis of neonatal sepsis]. — Research Paper | ScholarLens