2006PubMedRequires access

[Use of intraoperative round window electrocochleography for assessment of cochlear implantation safety].

Lin'e Wang, Keli Cao, Zhen Wang

Open publisher page 3 citations

Abstract

OBJECTIVE: To objectively evaluate whether cochlear implantation surgery made damage to cochlear basal membrane or not through analyzing the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. METHOD: Round window electrocochleography was performed on 40 cases with profound sensorineural deafness under general anesthesia in the standard operating room in order to analyze the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. RESULT: Among the 40 cases, thresholds of cochlear microphonic (CM) before and after inserting electrode during cochlear implantation surgery were similar in 39 cases. The thresholds of cochlear microphonic (CM) after inserting electrode decreased about 5 dB at certain frequency. The thresholds of cochlear microphonic (CM) after inserting electrode increased 20-50 dB in only one case. There was a sense of resistance in implanting the electrodes in this patient. CONCLUSION: Use of round window electrocochleography may objectively evaluate whether cochlear implantation surgery make damage to cochlear basal membrane or not.

About this research paper

What this paper is about

OBJECTIVE: To objectively evaluate whether cochlear implantation surgery made damage to cochlear basal membrane or not through analyzing the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. METHOD: Round window electrocochleography was performed on 40 cases with profound sensorineural deafness under general anesthesia in the standard operating room in order to analyze the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. RESULT: Among the 40 cases, thresholds of cochlear microphonic (CM) before and after inserting electrode during cochlear implantation surgery were similar in 39 cases. The thresholds of cochlear microphonic (CM) after inserting electrode decreased about 5 dB at certain frequency. The thresholds of cochlear microphonic (CM) after inserting electrode increased 20-50 dB in only one case. There was a sense of resistance in implanting the electrodes in this patient. CONCLUSION: Use of round window electrocochleography may objectively evaluate whether cochlear implantation surgery make damage to cochlear basal membrane or not.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To objectively evaluate whether cochlear implantation surgery made damage to cochlear basal membrane or not through analyzing the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. METHOD: Round window electrocochleography was performed on 40 cases with profound sensorineural deafness under general anesthesia in the standard operating room in order to analyze the change of the threshold of cochlear microphonic (CM) of round window electrocochleography before and after inserting electrode during cochlear implantation surgery. RESULT: Among the 40 cases, thresholds of cochlear microphonic (CM) before and after inserting electrode during cochlear implantation surgery were similar in 39 cases. The thresholds of cochlear microphonic (CM) after inserting electrode decreased about 5 dB at certain frequency. The thresholds of cochlear microphonic (CM) after inserting electrode increased 20-50 dB in only one case. There was a sense of resistance in implanting the electrodes in this patient. CONCLUSION: Use of round window electrocochleography may objectively evaluate whether cochlear implantation surgery make damage to cochlear basal membrane or not.

Key concepts: Electrocochleography, Round window, Cochlear implantation, Medicine, Audiology, Microphonics, Cochlea, Cochlear implant

Related papers

Back to paper searchBrowse research topicsOriginal source
[Use of intraoperative round window electrocochleography for assessment of cochlear implantation safety]. — Research Paper | ScholarLens