2001PubMedRequires access

[Influence of cornea thickness changes after refractive surgery on intraocular pressure measurements].

I Filipecka, Stanisława Gierek-Ciaciura

Open publisher page 3 citations

Abstract

PURPOSE: Assessment of influence of of the cornea thickness decrease on intraocular pressure (IOP) measurements with Goldmann applanation tonometry in patients after refractive surgery procedures (PRK and LASIK). MATERIAL AND METHODS: 80 eyes in 40 patients (pts) qualified for myopia correction with laser surgery were divided into two groups: in Ist group--20 pts (40 eyes)--PRK procedure was performed and in IInd group--40 eyes (20 pts) LASIK was performed. IOP was measured by Goldmann applanation tonometry. The cornea thickness was assessed in its central region with endothelial microscope with pachymetric facility (Cooper Vision). The eyes were evaluated twice: before and 1 month after the procedure. RESULTS: In all eyes after laser surgery procedures IOP was lower because of the decrease of central cornea thickness. CONCLUSIONS: The central cornea thickness is an important factor influencing intraocular pressure measurements with Goldmann applanation tonometry. Refractive surgery procedures leading to the decrease of central cornea thickness result in lower intraocular pressure measurements in applanation tonometry.

About this research paper

What this paper is about

PURPOSE: Assessment of influence of of the cornea thickness decrease on intraocular pressure (IOP) measurements with Goldmann applanation tonometry in patients after refractive surgery procedures (PRK and LASIK). MATERIAL AND METHODS: 80 eyes in 40 patients (pts) qualified for myopia correction with laser surgery were divided into two groups: in Ist group--20 pts (40 eyes)--PRK procedure was performed and in IInd group--40 eyes (20 pts) LASIK was performed. IOP was measured by Goldmann applanation tonometry. The cornea thickness was assessed in its central region with endothelial microscope with pachymetric facility (Cooper Vision). The eyes were evaluated twice: before and 1 month after the procedure. RESULTS: In all eyes after laser surgery procedures IOP was lower because of the decrease of central cornea thickness. CONCLUSIONS: The central cornea thickness is an important factor influencing intraocular pressure measurements with Goldmann applanation tonometry. Refractive surgery procedures leading to the decrease of central cornea thickness result in lower intraocular pressure measurements in applanation tonometry.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Assessment of influence of of the cornea thickness decrease on intraocular pressure (IOP) measurements with Goldmann applanation tonometry in patients after refractive surgery procedures (PRK and LASIK). MATERIAL AND METHODS: 80 eyes in 40 patients (pts) qualified for myopia correction with laser surgery were divided into two groups: in Ist group--20 pts (40 eyes)--PRK procedure was performed and in IInd group--40 eyes (20 pts) LASIK was performed. IOP was measured by Goldmann applanation tonometry. The cornea thickness was assessed in its central region with endothelial microscope with pachymetric facility (Cooper Vision). The eyes were evaluated twice: before and 1 month after the procedure. RESULTS: In all eyes after laser surgery procedures IOP was lower because of the decrease of central cornea thickness. CONCLUSIONS: The central cornea thickness is an important factor influencing intraocular pressure measurements with Goldmann applanation tonometry. Refractive surgery procedures leading to the decrease of central cornea thickness result in lower intraocular pressure measurements in applanation tonometry.

Key concepts: LASIK, Medicine, Cornea, Intraocular pressure, Ophthalmology, Refractive surgery, Applanation tonometry, Optometry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Influence of cornea thickness changes after refractive surgery on intraocular pressure measurements]. — Research Paper | ScholarLens