2003PubMedRequires access

A new technique for abdominal heart transplantation in rats.

Ergün Demirsoy, Harun Arbatlı, Ali Kubilay Korkut, Naci Yağan, Bircan Sönmez

Open publisher page 7 citations

Abstract

Experimental studies in animals play a major role in the progress of medicine. Different surgical techniques have been described for heterotopic heart transplantation in rats. In this study we introduce a new technique for heart transplantation in the abdominal cavity of rats. Fifteen Sprague Dawley rats have been used as recipients and 15 others as donors. Following preparation of recipient abdominal aorta and left renal vein, the donor heart including proximal arcus aorta was harvested. Donor aorta was anastomosed to the recipient's aorta; donor pulmonary artery was anastomosed to the left renal vein of the recipient using continuous suture technique. Graft function was evaluated daily by palpation of the rat abdomen. The mean operating time was 38.46+/-2.66 min and the mean ischemia time was 23.93+/-2.11 min. One death was seen because of bleeding of the aorto-aortic anastomosis. In this study we evaluated advantages and disadvantages of our technique and compared it to other techniques. This modification provides a more anatomical position, reduces exploration time, has a low incidence of morbidity and mortality. We conclude that, this implantation technique is more suitable for heterotopic heart transplantation in rats.

About this research paper

What this paper is about

Experimental studies in animals play a major role in the progress of medicine. Different surgical techniques have been described for heterotopic heart transplantation in rats. In this study we introduce a new technique for heart transplantation in the abdominal cavity of rats. Fifteen Sprague Dawley rats have been used as recipients and 15 others as donors. Following preparation of recipient abdominal aorta and left renal vein, the donor heart including proximal arcus aorta was harvested. Donor aorta was anastomosed to the recipient's aorta; donor pulmonary artery was anastomosed to the left renal vein of the recipient using continuous suture technique. Graft function was evaluated daily by palpation of the rat abdomen. The mean operating time was 38.46+/-2.66 min and the mean ischemia time was 23.93+/-2.11 min. One death was seen because of bleeding of the aorto-aortic anastomosis. In this study we evaluated advantages and disadvantages of our technique and compared it to other techniques. This modification provides a more anatomical position, reduces exploration time, has a low incidence of morbidity and mortality. We conclude that, this implantation technique is more suitable for heterotopic heart transplantation in rats.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Experimental studies in animals play a major role in the progress of medicine. Different surgical techniques have been described for heterotopic heart transplantation in rats. In this study we introduce a new technique for heart transplantation in the abdominal cavity of rats. Fifteen Sprague Dawley rats have been used as recipients and 15 others as donors. Following preparation of recipient abdominal aorta and left renal vein, the donor heart including proximal arcus aorta was harvested. Donor aorta was anastomosed to the recipient's aorta; donor pulmonary artery was anastomosed to the left renal vein of the recipient using continuous suture technique. Graft function was evaluated daily by palpation of the rat abdomen. The mean operating time was 38.46+/-2.66 min and the mean ischemia time was 23.93+/-2.11 min. One death was seen because of bleeding of the aorto-aortic anastomosis. In this study we evaluated advantages and disadvantages of our technique and compared it to other techniques. This modification provides a more anatomical position, reduces exploration time, has a low incidence of morbidity and mortality. We conclude that, this implantation technique is more suitable for heterotopic heart transplantation in rats.

Key concepts: Medicine, Abdominal aorta, Aorta, Transplantation, Anastomosis, Heart transplantation, Abdomen, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
A new technique for abdominal heart transplantation in rats. — Research Paper | ScholarLens