2015Advances in respiratory medicineOpen access

Association between Asthma Control Test, Pulmonary Function Tests and Non-Specific Bronchial Hyperresponsiveness in Assessing the Level of Asthma Control

I Grzelewska-Rzymowska, Joanna Mikołajczyk, Jadwiga Kroczyńska‐Bednarek, Paweł Górski

Open full text 4 citations

Abstract

INTRODUCTION: Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT). However, an ACT does not include assessment of airway inflammation, which is better reflected when measuring nonspecific bronchial hyperresponsiveness (BHR). The authors aimed to find out if the level of asthma control quantified by an ACT correlates with BHR and pulmonary function tests. MATERIAL AND METHODS: 118 asthmatics participated in the study. All patients completed an ACT. The scores of the ACTs were compared with pulmonary function tests and BHR assessed with the methacholine challenge test and expressed as a provocative concentration of methacholine, inducing a 20% decline in the FEV1 (PC20 M in mg/ml). RESULTS: Patients with controlled asthma amounted to 52 (44%) while those with uncontrolled asthma amounted to 66 (56%). In patients with controlled asthma (ACT score ≥ 20) the mean geometric value of PC20M was 2.72 mg/ml (range from 0.25 to > 8.0), whereas 0.94 mg/ml (range from 0.28 to 8.0) (p = 0.02) was observed in patients with uncontrolled asthma (ACT score < 20). Almost 64% (21/33) of uncontrolled asthmatics achieved normal lung function (FEV1 > 80% pred. value) while 19% (5/26) patients with controlled asthma presented an FEV1 < 80% predicted value. Asthma duration in years in controlled asthmatics was significantly shorter than in uncontrolled patients (6.2 ± 8.9 vs. 12.0 ± 11.4, p = 0.005) CONCLUSION: In determining the most accurate level of asthma control it is reasonable to use an ACT in conjunction with BHR, which provides more accurate assessment of bronchial inflammation than ventilatory parameters alone.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT). However, an ACT does not include assessment of airway inflammation, which is better reflected when measuring nonspecific bronchial hyperresponsiveness (BHR). The authors aimed to find out if the level of asthma control quantified by an ACT correlates with BHR and pulmonary function tests. MATERIAL AND METHODS: 118 asthmatics participated in the study. All patients completed an ACT. The scores of the ACTs were compared with pulmonary function tests and BHR assessed with the methacholine challenge test and expressed as a provocative concentration of methacholine, inducing a 20% decline in the FEV1 (PC20 M in mg/ml). RESULTS: Patients with controlled asthma amounted to 52 (44%) while those with uncontrolled asthma amounted to 66 (56%). In patients with controlled asthma (ACT score ≥ 20) the mean geometric value of PC20M was 2.72 mg/ml (range from 0.25 to > 8.0), whereas 0.94 mg/ml (range from 0.28 to 8.0) (p = 0.02) was observed in patients with uncontrolled asthma (ACT score < 20). Almost 64% (21/33) of uncontrolled asthmatics achieved normal lung function (FEV1 > 80% pred. value) while 19% (5/26) patients with controlled asthma presented an FEV1 < 80% predicted value. Asthma duration in years in controlled asthmatics was significantly shorter than in uncontrolled patients (6.2 ± 8.9 vs. 12.0 ± 11.4, p = 0.005) CONCLUSION: In determining the most accurate level of asthma control it is reasonable to use an ACT in conjunction with BHR, which provides more accurate assessment of bronchial inflammation than ventilatory parameters alone.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT). However, an ACT does not include assessment of airway inflammation, which is better reflected when measuring nonspecific bronchial hyperresponsiveness (BHR). The authors aimed to find out if the level of asthma control quantified by an ACT correlates with BHR and pulmonary function tests. MATERIAL AND METHODS: 118 asthmatics participated in the study. All patients completed an ACT. The scores of the ACTs were compared with pulmonary function tests and BHR assessed with the methacholine challenge test and expressed as a provocative concentration of methacholine, inducing a 20% decline in the FEV1 (PC20 M in mg/ml). RESULTS: Patients with controlled asthma amounted to 52 (44%) while those with uncontrolled asthma amounted to 66 (56%). In patients with controlled asthma (ACT score ≥ 20) the mean geometric value of PC20M was 2.72 mg/ml (range from 0.25 to > 8.0), whereas 0.94 mg/ml (range from 0.28 to 8.0) (p = 0.02) was observed in patients with uncontrolled asthma (ACT score < 20). Almost 64% (21/33) of uncontrolled asthmatics achieved normal lung function (FEV1 > 80% pred. value) while 19% (5/26) patients with controlled asthma presented an FEV1 < 80% predicted value. Asthma duration in years in controlled asthmatics was significantly shorter than in uncontrolled patients (6.2 ± 8.9 vs. 12.0 ± 11.4, p = 0.005) CONCLUSION: In determining the most accurate level of asthma control it is reasonable to use an ACT in conjunction with BHR, which provides more accurate assessment of bronchial inflammation than ventilatory parameters alone.

Key concepts: Asthma, Medicine, Bronchial hyperresponsiveness, Methacholine, Pulmonary function testing, Airway hyperresponsiveness, Internal medicine, Lung function

Related papers

Back to paper searchBrowse research topicsOriginal source
Association between Asthma Control Test, Pulmonary Function Tests and Non-Specific Bronchial Hyperresponsiveness in Assessing the Level of Asthma Control — Research Paper | ScholarLens