1996PubMedRequires access

Development of an antigen capture enzyme immuno assay using genus specific monoclonal antibodies for detection of Chlamydia in clinical specimens.

Sujit K. Mohanty, Gita Satpathy, Suresh K. Mittal, Panda Sk

Open publisher page 4 citations

Abstract

An antigen capture enzyme immuno assay (EIA) for Chlamydia antigen detection was developed using polyclonal rabbit immunoglobulins against C. trachomatis, a genus specific antichlamydial murine monoclonal antibody (IgG) against major outer membrane protein (MOMP) antigen of C. trachomatis and a commercial anti mouse IgG immunoglobulin conjugated with HRPO. The test was evaluated against a direct immunofluorescence assay (DFA). Conjunctival specimens from 178 patients with follicular conjunctivitis and cervical specimens from 82 patients with cervicitis were tested for Chlamydia antigen detection by both the tests. Chlamydia antigen was detected in 69/178 (38.76%) and 68/178 (38.20%) of the conjunctival specimen by using EIA and DFA tests respectively. It could also be detected in 24/82 (29.27%) and 22/82 (26.83%) of the cervical specimens by EIA and DFA tests respectively. The sensitivity of the EIA test was 92.64 per cent and 86.36 per cent for the conjunctival and cervical specimens respectively against the reference DFA test. The specificity of the EIA test was found to be 94.54 and 91.66 per cent respectively against the reference DFA test.

About this research paper

What this paper is about

An antigen capture enzyme immuno assay (EIA) for Chlamydia antigen detection was developed using polyclonal rabbit immunoglobulins against C. trachomatis, a genus specific antichlamydial murine monoclonal antibody (IgG) against major outer membrane protein (MOMP) antigen of C. trachomatis and a commercial anti mouse IgG immunoglobulin conjugated with HRPO. The test was evaluated against a direct immunofluorescence assay (DFA). Conjunctival specimens from 178 patients with follicular conjunctivitis and cervical specimens from 82 patients with cervicitis were tested for Chlamydia antigen detection by both the tests. Chlamydia antigen was detected in 69/178 (38.76%) and 68/178 (38.20%) of the conjunctival specimen by using EIA and DFA tests respectively. It could also be detected in 24/82 (29.27%) and 22/82 (26.83%) of the cervical specimens by EIA and DFA tests respectively. The sensitivity of the EIA test was 92.64 per cent and 86.36 per cent for the conjunctival and cervical specimens respectively against the reference DFA test. The specificity of the EIA test was found to be 94.54 and 91.66 per cent respectively against the reference DFA test.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An antigen capture enzyme immuno assay (EIA) for Chlamydia antigen detection was developed using polyclonal rabbit immunoglobulins against C. trachomatis, a genus specific antichlamydial murine monoclonal antibody (IgG) against major outer membrane protein (MOMP) antigen of C. trachomatis and a commercial anti mouse IgG immunoglobulin conjugated with HRPO. The test was evaluated against a direct immunofluorescence assay (DFA). Conjunctival specimens from 178 patients with follicular conjunctivitis and cervical specimens from 82 patients with cervicitis were tested for Chlamydia antigen detection by both the tests. Chlamydia antigen was detected in 69/178 (38.76%) and 68/178 (38.20%) of the conjunctival specimen by using EIA and DFA tests respectively. It could also be detected in 24/82 (29.27%) and 22/82 (26.83%) of the cervical specimens by EIA and DFA tests respectively. The sensitivity of the EIA test was 92.64 per cent and 86.36 per cent for the conjunctival and cervical specimens respectively against the reference DFA test. The specificity of the EIA test was found to be 94.54 and 91.66 per cent respectively against the reference DFA test.

Key concepts: Antigen, Chlamydia trachomatis, Polyclonal antibodies, Chlamydia, Antibody, Immunofluorescence, Monoclonal antibody, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of an antigen capture enzyme immuno assay using genus specific monoclonal antibodies for detection of Chlamydia in clinical specimens. — Research Paper | ScholarLens