2009PubMedRequires access

[Correlation between four-phase rhinomanometry and acoustic rhinometry].

Chunting Cao, Demin Han, Luo Zhang

Open publisher page 3 citations

Abstract

OBJECTIVE: To obtain the normal values of four-phase rhinomanometry specific parameters of normal adult Chinese and analyze the correlation between four-phase rhinomanometry and acoustic rhinometry measurement results. METHODS: Eighty-five normal adults were recruited. The HRR2 four-phase rhinomanometry was used to acquire the effective resistances in inspiration, expiration and total breathing process (Reffin, Reffex, Refft) and vertex resistance in the process of inspiration and expiration (Vrin and Vrex). The Eccovision acoustic rhinometry was used to measure the minimum cross-sectional area (MCA) and the nasal volume of 0-5 cm nasal cavity (V5). RESULTS: Reffin (x(-) +/- s) was (1.28 +/- 1.02) Pa/(cm(3).s) for male, (1.55 +/- 1.03) Pa/(cm(3).s) for female; Reflex (x(-) +/- s) was (1.43 +/- 1.07) Pa/(cm(3).s) for male, (1.75 +/- 1.14) Pa/(cm(3).s) for female; Refft (x(-) +/- s) was (1.34 +/- 0.99) Pa/(cm(3).s) for male, (1.62 +/- 1.03) Pa/(cm(3).s) for female; Vrin (x(-) +/- s) was (1.31 +/- 1.03) Pa/(cm(3).s) for male; (1.60 +/- 1.03) Pa/(cm(3).s) for female, Vrex (x(-) +/- s) was (1.46 +/- 1.04) Pa/(cm(3).s) for male, (1.82 +/- 1.17) Pa/(cm(3).s) for female. No statistically significant difference was found between men and women (r = 0.661, -0.397, 0.127, 0.649, -0.684, P > 0.05, respectively). There was no significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and age, height, weight, head circumference, body surface area, body mass index (P > 0.05, respectively). However, there was significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and MCA, V5 (P < 0.05, respectively). CONCLUSIONS: The results of four-phase rhinomanometry show significant correlation to acoustic rhinometry.

About this research paper

What this paper is about

OBJECTIVE: To obtain the normal values of four-phase rhinomanometry specific parameters of normal adult Chinese and analyze the correlation between four-phase rhinomanometry and acoustic rhinometry measurement results. METHODS: Eighty-five normal adults were recruited. The HRR2 four-phase rhinomanometry was used to acquire the effective resistances in inspiration, expiration and total breathing process (Reffin, Reffex, Refft) and vertex resistance in the process of inspiration and expiration (Vrin and Vrex). The Eccovision acoustic rhinometry was used to measure the minimum cross-sectional area (MCA) and the nasal volume of 0-5 cm nasal cavity (V5). RESULTS: Reffin (x(-) +/- s) was (1.28 +/- 1.02) Pa/(cm(3).s) for male, (1.55 +/- 1.03) Pa/(cm(3).s) for female; Reflex (x(-) +/- s) was (1.43 +/- 1.07) Pa/(cm(3).s) for male, (1.75 +/- 1.14) Pa/(cm(3).s) for female; Refft (x(-) +/- s) was (1.34 +/- 0.99) Pa/(cm(3).s) for male, (1.62 +/- 1.03) Pa/(cm(3).s) for female; Vrin (x(-) +/- s) was (1.31 +/- 1.03) Pa/(cm(3).s) for male; (1.60 +/- 1.03) Pa/(cm(3).s) for female, Vrex (x(-) +/- s) was (1.46 +/- 1.04) Pa/(cm(3).s) for male, (1.82 +/- 1.17) Pa/(cm(3).s) for female. No statistically significant difference was found between men and women (r = 0.661, -0.397, 0.127, 0.649, -0.684, P > 0.05, respectively). There was no significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and age, height, weight, head circumference, body surface area, body mass index (P > 0.05, respectively). However, there was significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and MCA, V5 (P < 0.05, respectively). CONCLUSIONS: The results of four-phase rhinomanometry show significant correlation to acoustic rhinometry.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To obtain the normal values of four-phase rhinomanometry specific parameters of normal adult Chinese and analyze the correlation between four-phase rhinomanometry and acoustic rhinometry measurement results. METHODS: Eighty-five normal adults were recruited. The HRR2 four-phase rhinomanometry was used to acquire the effective resistances in inspiration, expiration and total breathing process (Reffin, Reffex, Refft) and vertex resistance in the process of inspiration and expiration (Vrin and Vrex). The Eccovision acoustic rhinometry was used to measure the minimum cross-sectional area (MCA) and the nasal volume of 0-5 cm nasal cavity (V5). RESULTS: Reffin (x(-) +/- s) was (1.28 +/- 1.02) Pa/(cm(3).s) for male, (1.55 +/- 1.03) Pa/(cm(3).s) for female; Reflex (x(-) +/- s) was (1.43 +/- 1.07) Pa/(cm(3).s) for male, (1.75 +/- 1.14) Pa/(cm(3).s) for female; Refft (x(-) +/- s) was (1.34 +/- 0.99) Pa/(cm(3).s) for male, (1.62 +/- 1.03) Pa/(cm(3).s) for female; Vrin (x(-) +/- s) was (1.31 +/- 1.03) Pa/(cm(3).s) for male; (1.60 +/- 1.03) Pa/(cm(3).s) for female, Vrex (x(-) +/- s) was (1.46 +/- 1.04) Pa/(cm(3).s) for male, (1.82 +/- 1.17) Pa/(cm(3).s) for female. No statistically significant difference was found between men and women (r = 0.661, -0.397, 0.127, 0.649, -0.684, P > 0.05, respectively). There was no significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and age, height, weight, head circumference, body surface area, body mass index (P > 0.05, respectively). However, there was significant correlation between Reffin, Reflex, Refft, Vrin, Vrex and MCA, V5 (P < 0.05, respectively). CONCLUSIONS: The results of four-phase rhinomanometry show significant correlation to acoustic rhinometry.

Key concepts: Acoustic rhinometry, Rhinomanometry, Medicine, Expiration, Correlation, Nuclear medicine, Nose, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
[Correlation between four-phase rhinomanometry and acoustic rhinometry]. — Research Paper | ScholarLens