1992American Journal of HypertensionRequires access

Comparison of Ambulatory and Clinic Blood Pressure and Heart Rate in Older Persons With Isolated Systolic Hypertension

Gale H. Rutan, Robert H. McDonald, Lewis H. Kuller

Open publisher page 6 citations

Abstract

We compared the blood pressure (BP) measurements obtained with a random-zero sphygmomanometer and an ambulatory BP monitor in older persons with isolated systolic hypertension at one site of the multicenter, randomized, double-blind clinical trial, the Systolic Hypertension in the Elderly Program (SHEP) randomized clinical trial. The subjects were community-dwelling elderly participants with isolated systolic hypertension enrolled in the SHEP study and already receiving stable doses of double-blind medication (n = 35 for active treatment group; n = 32 for placebo group). We measured seated (clinic) BP obtained with a random-zero sphygmomamanometer, pulse rate, and BP and heart rate measurements obtained with an ambulatory BP monitor (average 24 h, daytime, and nighttime BP and heart rate). Across treatment groups clinic and ambulatory systolic BPs were not significantly different, but the placebo group had higher ambulatory, but not clinic, diastolic BPs. Within each treatment group (active treatment and placebo) there were no significant differences between clinic and average 24 h, daytime, or nighttime ambulatory systolic BPs. There were also no significant differences between clinic diastolic BP and average 24 h, daytime, or nighttime ambulatory diastolic BPs in the active treatment group, but in the placebo group average 24 h diastolic BP obtained by the ambulatory monitor was 4.6 mm Hg higher than clinic diastolic BP (P = .001). The average 24 h heart rate was 6 to 7 beats/min higher as measured by the ambulatory monitor compared to clinic pulse (P < .01). In the placebo group of this study, average 24 h ambulatory diastolic BPs were consistently higher than clinic diastolic BPs.(ABSTRACT TRUNCATED AT 250 WORDS)

About this research paper

What this paper is about

We compared the blood pressure (BP) measurements obtained with a random-zero sphygmomanometer and an ambulatory BP monitor in older persons with isolated systolic hypertension at one site of the multicenter, randomized, double-blind clinical trial, the Systolic Hypertension in the Elderly Program (SHEP) randomized clinical trial. The subjects were community-dwelling elderly participants with isolated systolic hypertension enrolled in the SHEP study and already receiving stable doses of double-blind medication (n = 35 for active treatment group; n = 32 for placebo group). We measured seated (clinic) BP obtained with a random-zero sphygmomamanometer, pulse rate, and BP and heart rate measurements obtained with an ambulatory BP monitor (average 24 h, daytime, and nighttime BP and heart rate). Across treatment groups clinic and ambulatory systolic BPs were not significantly different, but the placebo group had higher ambulatory, but not clinic, diastolic BPs. Within each treatment group (active treatment and placebo) there were no significant differences between clinic and average 24 h, daytime, or nighttime ambulatory systolic BPs. There were also no significant differences between clinic diastolic BP and average 24 h, daytime, or nighttime ambulatory diastolic BPs in the active treatment group, but in the placebo group average 24 h diastolic BP obtained by the ambulatory monitor was 4.6 mm Hg higher than clinic diastolic BP (P = .001). The average 24 h heart rate was 6 to 7 beats/min higher as measured by the ambulatory monitor compared to clinic pulse (P < .01). In the placebo group of this study, average 24 h ambulatory diastolic BPs were consistently higher than clinic diastolic BPs.(ABSTRACT TRUNCATED AT 250 WORDS)

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared the blood pressure (BP) measurements obtained with a random-zero sphygmomanometer and an ambulatory BP monitor in older persons with isolated systolic hypertension at one site of the multicenter, randomized, double-blind clinical trial, the Systolic Hypertension in the Elderly Program (SHEP) randomized clinical trial. The subjects were community-dwelling elderly participants with isolated systolic hypertension enrolled in the SHEP study and already receiving stable doses of double-blind medication (n = 35 for active treatment group; n = 32 for placebo group). We measured seated (clinic) BP obtained with a random-zero sphygmomamanometer, pulse rate, and BP and heart rate measurements obtained with an ambulatory BP monitor (average 24 h, daytime, and nighttime BP and heart rate). Across treatment groups clinic and ambulatory systolic BPs were not significantly different, but the placebo group had higher ambulatory, but not clinic, diastolic BPs. Within each treatment group (active treatment and placebo) there were no significant differences between clinic and average 24 h, daytime, or nighttime ambulatory systolic BPs. There were also no significant differences between clinic diastolic BP and average 24 h, daytime, or nighttime ambulatory diastolic BPs in the active treatment group, but in the placebo group average 24 h diastolic BP obtained by the ambulatory monitor was 4.6 mm Hg higher than clinic diastolic BP (P = .001). The average 24 h heart rate was 6 to 7 beats/min higher as measured by the ambulatory monitor compared to clinic pulse (P < .01). In the placebo group of this study, average 24 h ambulatory diastolic BPs were consistently higher than clinic diastolic BPs.(ABSTRACT TRUNCATED AT 250 WORDS)

Key concepts: Medicine, Ambulatory blood pressure, Ambulatory, Blood pressure, Diastole, Placebo, Sphygmomanometer, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Ambulatory and Clinic Blood Pressure and Heart Rate in Older Persons With Isolated Systolic Hypertension — Research Paper | ScholarLens