1991•American Journal of Physiology-Heart and Circulatory PhysiologyRequires access

Effect of skin concavity on subcutaneous tissue fluid pressure

Thomas H. Adair, Gregory Vance, J. P. Montani, Arthur C. Guyton

Open publisher page 7 citations

Abstract

We tested the hypothesis that mechanical factors associated, with a skin concavity can cause the local tissue fluid pressure to become more negative. Perforated Teflon collars, 26 mm in diameter and having various heights (5, 10, 13, and 16 mm), were implanted into the fascial plane of the inguinal and abdominal areas of six sheep. After several weeks, visible signs of edema were no longer apparent, and the skin formed a concavity within the center of each collar. The depth of each concavity was measured using an electronic micrometer, and the tissue fluid pressure beneath the concavity was measured using a needle method. Over the entire range of collar heights, the average depth of the concavities ranged from 1.1 to 4.7 mm in the abdominal tissues and from 1.8 to 5.5 mm in the inguinal tissues. The respective values of tissue fluid pressure averaged -4.6 to -13.0 and -5.7 to -12.8 mmHg. The results therefore indicate that implanting deeper collars leads to the formation of deeper concavities in the skin and also to greater negativity in the free tissue fluid pressure beneath the skin. Linear regression extrapolation to a collar height of 0 mm corresponded to a tissue fluid pressure of -1.0 mmHg in the abdominal tissue and -2.4 mmHg in the inguinal tissues. A model based on excessive pumping of the lymphatic system in the vicinity of a concavity is provided to explain this newly described phenomenon. We conclude that mechanical factors associated with the formation of a skin concavity cause or permit the tissue fluid pressure to reach levels of negativity far greater than those that exist in the absence of a concavity.

About this research paper

What this paper is about

We tested the hypothesis that mechanical factors associated, with a skin concavity can cause the local tissue fluid pressure to become more negative. Perforated Teflon collars, 26 mm in diameter and having various heights (5, 10, 13, and 16 mm), were implanted into the fascial plane of the inguinal and abdominal areas of six sheep. After several weeks, visible signs of edema were no longer apparent, and the skin formed a concavity within the center of each collar. The depth of each concavity was measured using an electronic micrometer, and the tissue fluid pressure beneath the concavity was measured using a needle method. Over the entire range of collar heights, the average depth of the concavities ranged from 1.1 to 4.7 mm in the abdominal tissues and from 1.8 to 5.5 mm in the inguinal tissues. The respective values of tissue fluid pressure averaged -4.6 to -13.0 and -5.7 to -12.8 mmHg. The results therefore indicate that implanting deeper collars leads to the formation of deeper concavities in the skin and also to greater negativity in the free tissue fluid pressure beneath the skin. Linear regression extrapolation to a collar height of 0 mm corresponded to a tissue fluid pressure of -1.0 mmHg in the abdominal tissue and -2.4 mmHg in the inguinal tissues. A model based on excessive pumping of the lymphatic system in the vicinity of a concavity is provided to explain this newly described phenomenon. We conclude that mechanical factors associated with the formation of a skin concavity cause or permit the tissue fluid pressure to reach levels of negativity far greater than those that exist in the absence of a concavity.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We tested the hypothesis that mechanical factors associated, with a skin concavity can cause the local tissue fluid pressure to become more negative. Perforated Teflon collars, 26 mm in diameter and having various heights (5, 10, 13, and 16 mm), were implanted into the fascial plane of the inguinal and abdominal areas of six sheep. After several weeks, visible signs of edema were no longer apparent, and the skin formed a concavity within the center of each collar. The depth of each concavity was measured using an electronic micrometer, and the tissue fluid pressure beneath the concavity was measured using a needle method. Over the entire range of collar heights, the average depth of the concavities ranged from 1.1 to 4.7 mm in the abdominal tissues and from 1.8 to 5.5 mm in the inguinal tissues. The respective values of tissue fluid pressure averaged -4.6 to -13.0 and -5.7 to -12.8 mmHg. The results therefore indicate that implanting deeper collars leads to the formation of deeper concavities in the skin and also to greater negativity in the free tissue fluid pressure beneath the skin. Linear regression extrapolation to a collar height of 0 mm corresponded to a tissue fluid pressure of -1.0 mmHg in the abdominal tissue and -2.4 mmHg in the inguinal tissues. A model based on excessive pumping of the lymphatic system in the vicinity of a concavity is provided to explain this newly described phenomenon. We conclude that mechanical factors associated with the formation of a skin concavity cause or permit the tissue fluid pressure to reach levels of negativity far greater than those that exist in the absence of a concavity.

Key concepts: Tissue fluid, Subcutaneous tissue, Interstitial fluid, Fluid pressure, Anatomy, Biomedical engineering, Medicine, Lymphatic system