Intraocular pressure measurement in patients with instrastromal corneal ring segments.
Dan B. Tran, David Zadok, M. B. CARPENTER, Thomas Korn, Michael D. Twa, David J. Schanzlin, T S Kom
Abstract
Dan B. Tran, David Zadok, M. B. CARPENTER, Thomas Korn, Michael D. Twa, David J. Schanzlin, T S Kom
Abstract
PURPOSE: To study the measurement of intraocular pressure after implantation of Intacs (ICRS) intrastromal corneal ring segment, a device that is positioned circumferentially in the peripheral corneal stroma to correct myopia. The device changes the corneal curvature by shortening arc length. Since the ring segments are made of polymethylmethacrylate, this may cause localized changes in corneal elasticity so intraocular pressure measurement may be affected. METHODS: We measured the intraocular pressure of 12 eyes in which the ICRS had been in place longer than 6 months. We used Goldmann applanation and Tono-Pen tonometers over the central corneal and the paracentral corneal areas. We also measured the intraocular pressure with the Tono-Pen applanated directly over the intrastromal corneal ring segments. RESULTS: The resulting intraocular pressure measurements were similar for the Tono-Pen tonometer readings over the central cornea, paracentral cornea, and the Goldmann applanation tonometer readings over the central cornea (P < .01). Our measurements using the Goldmann applanation tonometer on the paracentral corneal area showed artificially elevated intraocular pressure in the 40 to 60 mmHg range. We were not able to obtain consistent results when we measured the intraocular pressure using the Tono-Pen on the corneal area directly overlying the intrastromal corneal ring segment implants. CONCLUSION: Consistent intraocular pressure measurements on eyes with the ICRS can be obtained with the Goldmann applanation tonometer over the central corneal area or with the Tono-Pen tonometer over the central or paracentral corneal areas.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To study the measurement of intraocular pressure after implantation of Intacs (ICRS) intrastromal corneal ring segment, a device that is positioned circumferentially in the peripheral corneal stroma to correct myopia. The device changes the corneal curvature by shortening arc length. Since the ring segments are made of polymethylmethacrylate, this may cause localized changes in corneal elasticity so intraocular pressure measurement may be affected. METHODS: We measured the intraocular pressure of 12 eyes in which the ICRS had been in place longer than 6 months. We used Goldmann applanation and Tono-Pen tonometers over the central corneal and the paracentral corneal areas. We also measured the intraocular pressure with the Tono-Pen applanated directly over the intrastromal corneal ring segments. RESULTS: The resulting intraocular pressure measurements were similar for the Tono-Pen tonometer readings over the central cornea, paracentral cornea, and the Goldmann applanation tonometer readings over the central cornea (P < .01). Our measurements using the Goldmann applanation tonometer on the paracentral corneal area showed artificially elevated intraocular pressure in the 40 to 60 mmHg range. We were not able to obtain consistent results when we measured the intraocular pressure using the Tono-Pen on the corneal area directly overlying the intrastromal corneal ring segment implants. CONCLUSION: Consistent intraocular pressure measurements on eyes with the ICRS can be obtained with the Goldmann applanation tonometer over the central corneal area or with the Tono-Pen tonometer over the central or paracentral corneal areas.
Key concepts: Medicine, Intraocular pressure, Ophthalmology, Goldmann Applanation Tonometer, Cornea, Applanation tonometry, Corneal pachymetry, Keratoconus