1994PubMedRequires access

[The VO2 performance index for evaluation of cardiopulmonary capacity in respiratory minute volume controlled VVI-R stimulation].

S Epperlein, N. Treese, A Stegmaier, Mariana Coutinho, J Meyer

Open publisher page 1 citations

Abstract

This study was designed to assess the effect of acute minute ventilation sensing, rate-responsive pacing on cardiopulmonary exercise capacity in 27 patients (mean age 60 years) with chronotropic incompetence. The exercise protocol consisted of bicycle exercise in semisupine position with breath-to-breath analysis of gas exchange. At the anaerobic threshold heart rate increased from 75 +/- 9 in the VVI-mode to 113 +/- 21 beats/min in the VVI-R-mode (p < 0.001), oxygen uptake from 9.3 +/- 3.4 to 10.9 +/- 4.3 ml/kg/min (p < 0.001) and work rate from 52 +/- 20 to 65 +/- 24 watts (p < 0.001). Compared to 41 normal subjects, VVI-R pacing increased oxygen uptake up to 75% and work rate up to 79% of normal values, while heart rate increased similarly in both groups. The VO2 to work rate ratio (dVO2/dWR), calculated as the slope of the relation of oxygen uptake to work rate below the anaerobic threshold, improved from 7.9 +/- 2.3 to 10.2 +/- 2.4 ml/min/watts (p < 0.001) in the VVI-R-mode; so it did not differ from normal values. Thus, acute respiratory dependent rate-responsive pacing results in substantial improvement in cardiopulmonary exercise capacity in patients with chronotropic incompetence. The VO2 to work rate ratio demonstrated to be a reliable parameter for assessing this improvement.

About this research paper

What this paper is about

This study was designed to assess the effect of acute minute ventilation sensing, rate-responsive pacing on cardiopulmonary exercise capacity in 27 patients (mean age 60 years) with chronotropic incompetence. The exercise protocol consisted of bicycle exercise in semisupine position with breath-to-breath analysis of gas exchange. At the anaerobic threshold heart rate increased from 75 +/- 9 in the VVI-mode to 113 +/- 21 beats/min in the VVI-R-mode (p < 0.001), oxygen uptake from 9.3 +/- 3.4 to 10.9 +/- 4.3 ml/kg/min (p < 0.001) and work rate from 52 +/- 20 to 65 +/- 24 watts (p < 0.001). Compared to 41 normal subjects, VVI-R pacing increased oxygen uptake up to 75% and work rate up to 79% of normal values, while heart rate increased similarly in both groups. The VO2 to work rate ratio (dVO2/dWR), calculated as the slope of the relation of oxygen uptake to work rate below the anaerobic threshold, improved from 7.9 +/- 2.3 to 10.2 +/- 2.4 ml/min/watts (p < 0.001) in the VVI-R-mode; so it did not differ from normal values. Thus, acute respiratory dependent rate-responsive pacing results in substantial improvement in cardiopulmonary exercise capacity in patients with chronotropic incompetence. The VO2 to work rate ratio demonstrated to be a reliable parameter for assessing this improvement.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study was designed to assess the effect of acute minute ventilation sensing, rate-responsive pacing on cardiopulmonary exercise capacity in 27 patients (mean age 60 years) with chronotropic incompetence. The exercise protocol consisted of bicycle exercise in semisupine position with breath-to-breath analysis of gas exchange. At the anaerobic threshold heart rate increased from 75 +/- 9 in the VVI-mode to 113 +/- 21 beats/min in the VVI-R-mode (p < 0.001), oxygen uptake from 9.3 +/- 3.4 to 10.9 +/- 4.3 ml/kg/min (p < 0.001) and work rate from 52 +/- 20 to 65 +/- 24 watts (p < 0.001). Compared to 41 normal subjects, VVI-R pacing increased oxygen uptake up to 75% and work rate up to 79% of normal values, while heart rate increased similarly in both groups. The VO2 to work rate ratio (dVO2/dWR), calculated as the slope of the relation of oxygen uptake to work rate below the anaerobic threshold, improved from 7.9 +/- 2.3 to 10.2 +/- 2.4 ml/min/watts (p < 0.001) in the VVI-R-mode; so it did not differ from normal values. Thus, acute respiratory dependent rate-responsive pacing results in substantial improvement in cardiopulmonary exercise capacity in patients with chronotropic incompetence. The VO2 to work rate ratio demonstrated to be a reliable parameter for assessing this improvement.

Key concepts: Medicine, Chronotropic, Anaerobic exercise, Respiratory minute volume, Heart rate, Work rate, Respiratory exchange ratio, Ventilation (architecture)

Related papers

Back to paper searchBrowse research topicsOriginal source
[The VO2 performance index for evaluation of cardiopulmonary capacity in respiratory minute volume controlled VVI-R stimulation]. — Research Paper | ScholarLens