1981PubMedRequires access

[Clinical evaluation of cardiac function test using scintiview (author's transl)].

Yoshiya Miyazaki, M Fujioka, Hiroshi Inoue, Edo S, Chieko ISHIMOTO, Masanori Kawasaki, Miyoshi URABE, Yutaka Wakasa, Y. Murata, S Muramoto, Tatsuro Hiraki

Open publisher page 0 citations

Abstract

Cardiac function was studied with Scintiview in 107 cases, 24 normal and 83 affected cases, and the following results were obtained. 1. Better data were obtained with converging collimeter than with parallel collimeter in cardiac study. (2) Red blood cells were sufficiently labeled with 99mTc using stannous chloride as reductant, and it was proven to be applicable to measurement of circulation blood volume. (3) Pulmonary circulation time and the systemic circulation time calculated from time activity curve, greater than 9.0 seconds and greater than 25 seconds, respectively, were considered abnormal prolongation. (4) Cardiac output index (cardiac output/circulation blood volume), less than 1.10 was considered decreased cardiac output. (5) Stroke volume index ((stroke volume/circulation blood volume)x 100, less than 1.70 was considered decreased stroke volume. (6) Ejection fraction, less than 60% was considered decreased left ventricular wall motion. (7) Cardiac function index (cardiac output index X ejection fraction), less than 80 was considered decreased cardiac performance.

About this research paper

What this paper is about

Cardiac function was studied with Scintiview in 107 cases, 24 normal and 83 affected cases, and the following results were obtained. 1. Better data were obtained with converging collimeter than with parallel collimeter in cardiac study. (2) Red blood cells were sufficiently labeled with 99mTc using stannous chloride as reductant, and it was proven to be applicable to measurement of circulation blood volume. (3) Pulmonary circulation time and the systemic circulation time calculated from time activity curve, greater than 9.0 seconds and greater than 25 seconds, respectively, were considered abnormal prolongation. (4) Cardiac output index (cardiac output/circulation blood volume), less than 1.10 was considered decreased cardiac output. (5) Stroke volume index ((stroke volume/circulation blood volume)x 100, less than 1.70 was considered decreased stroke volume. (6) Ejection fraction, less than 60% was considered decreased left ventricular wall motion. (7) Cardiac function index (cardiac output index X ejection fraction), less than 80 was considered decreased cardiac performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cardiac function was studied with Scintiview in 107 cases, 24 normal and 83 affected cases, and the following results were obtained. 1. Better data were obtained with converging collimeter than with parallel collimeter in cardiac study. (2) Red blood cells were sufficiently labeled with 99mTc using stannous chloride as reductant, and it was proven to be applicable to measurement of circulation blood volume. (3) Pulmonary circulation time and the systemic circulation time calculated from time activity curve, greater than 9.0 seconds and greater than 25 seconds, respectively, were considered abnormal prolongation. (4) Cardiac output index (cardiac output/circulation blood volume), less than 1.10 was considered decreased cardiac output. (5) Stroke volume index ((stroke volume/circulation blood volume)x 100, less than 1.70 was considered decreased stroke volume. (6) Ejection fraction, less than 60% was considered decreased left ventricular wall motion. (7) Cardiac function index (cardiac output index X ejection fraction), less than 80 was considered decreased cardiac performance.

Key concepts: Stroke volume, Cardiac output, Cardiac function curve, Cardiac index, Ejection fraction, Cardiology, Medicine, Blood volume

Related papers

Back to paper searchBrowse research topicsOriginal source
[Clinical evaluation of cardiac function test using scintiview (author's transl)]. — Research Paper | ScholarLens