2015PubMedOpen access

Comparison of the effect of the Trendelenburg and passive leg raising positions on internal jugular vein size in critically ill patients.

Funda Gök, Gamze Sarkılar, Alper Kılıçaslan, Alper Yosunkaya, Sema Tuncer Uzun

Open full text 17 citations

Abstract

Central vein catheterization is a common procedure performed on patients under intensive care. The safe and successful placement of the central venous catheter depends on vein size. Although used for this purpose, the Trendelenburg position can be hazardous in some patients. The aim of this study was to compare the effects of the Trendelenburg and passive leg raising (PLR) positions on the size of the right internal jugular vein (IJV) in mechanically ventilated patients under intensive care. Seventy-eight mechanically ventilated patients under intensive care were included into the study. Sonographic images of the right IJV were recorded in supine (control), 10° Trendelenburg and 40° PLR positions. Anterior-posterior and transverse diameter, cross-sectional area (CSA), and depth were calculated from the recorded images. The size of the right IJV (CSA, transverse and vertical diameters) was significantly larger in the Trendelenburg and PLR positions than in supine position. An increase of 26% in the IJV CSA was obtained in the Trendelenburg position and 23% in the PLR position, compared to the supine position. There was no significant difference between the measurements obtained from the Trendelenburg and PLR positions. The study shows that the Trendelenburg and PLR positions increase the size of the IJV to a similar extent in mechanically ventilated patients under intensive care.

About this research paper

What this paper is about

Central vein catheterization is a common procedure performed on patients under intensive care. The safe and successful placement of the central venous catheter depends on vein size. Although used for this purpose, the Trendelenburg position can be hazardous in some patients. The aim of this study was to compare the effects of the Trendelenburg and passive leg raising (PLR) positions on the size of the right internal jugular vein (IJV) in mechanically ventilated patients under intensive care. Seventy-eight mechanically ventilated patients under intensive care were included into the study. Sonographic images of the right IJV were recorded in supine (control), 10° Trendelenburg and 40° PLR positions. Anterior-posterior and transverse diameter, cross-sectional area (CSA), and depth were calculated from the recorded images. The size of the right IJV (CSA, transverse and vertical diameters) was significantly larger in the Trendelenburg and PLR positions than in supine position. An increase of 26% in the IJV CSA was obtained in the Trendelenburg position and 23% in the PLR position, compared to the supine position. There was no significant difference between the measurements obtained from the Trendelenburg and PLR positions. The study shows that the Trendelenburg and PLR positions increase the size of the IJV to a similar extent in mechanically ventilated patients under intensive care.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Central vein catheterization is a common procedure performed on patients under intensive care. The safe and successful placement of the central venous catheter depends on vein size. Although used for this purpose, the Trendelenburg position can be hazardous in some patients. The aim of this study was to compare the effects of the Trendelenburg and passive leg raising (PLR) positions on the size of the right internal jugular vein (IJV) in mechanically ventilated patients under intensive care. Seventy-eight mechanically ventilated patients under intensive care were included into the study. Sonographic images of the right IJV were recorded in supine (control), 10° Trendelenburg and 40° PLR positions. Anterior-posterior and transverse diameter, cross-sectional area (CSA), and depth were calculated from the recorded images. The size of the right IJV (CSA, transverse and vertical diameters) was significantly larger in the Trendelenburg and PLR positions than in supine position. An increase of 26% in the IJV CSA was obtained in the Trendelenburg position and 23% in the PLR position, compared to the supine position. There was no significant difference between the measurements obtained from the Trendelenburg and PLR positions. The study shows that the Trendelenburg and PLR positions increase the size of the IJV to a similar extent in mechanically ventilated patients under intensive care.

Key concepts: Trendelenburg, Trendelenburg position, Supine position, Medicine, Intensive care, Internal jugular vein, Anesthesia, Central venous catheter

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the effect of the Trendelenburg and passive leg raising positions on internal jugular vein size in critically ill patients. — Research Paper | ScholarLens