1994PubMedRequires access

Comparison of the bronchodilator response to albuterol administered by the OptiHaler, the AeroChamber, or by metered dose inhaler alone.

Harold S. Nelson, D LOFFERT

Open publisher page 17 citations

Abstract

Eighteen subjects with moderate asthma participated in this double-blind study comparing the bronchodilator response to albuterol or placebo used in conjunction with three inhalation devices; the metered dose inhaler (MDI) actuator alone, the AeroChamber, and the OptiHaler. The principal comparison was the increase in FEV1 over 30 minutes. Also recorded were heart rate, time required to use each device, and patient acceptance of each device. There was a large bronchodilator response with albuterol with each of the devices, but there was no difference in the promptness or the magnitude of the bronchodilator response among the three devices. There was a small but statistically significant increase in heart rate which did not differ among devices. Subject ratings of acceptability were MDI alone best, followed by OptiHaler, then AeroChamber. We conclude (1) the bronchodilator response obtained with use of the MDI alone, the AeroChamber and OptiHaler were not significantly different; (2) patients, as a group, found the MDI required less time to use and they favored it over either spacer; (3) while in subjects employing good MDI technique, the addition of either an AeroChamber or an OptiHaler did not improve bronchodilator response. Spacers may have a role in those with poor inhaler technique or in conjunction with inhaled corticosteroids.

About this research paper

What this paper is about

Eighteen subjects with moderate asthma participated in this double-blind study comparing the bronchodilator response to albuterol or placebo used in conjunction with three inhalation devices; the metered dose inhaler (MDI) actuator alone, the AeroChamber, and the OptiHaler. The principal comparison was the increase in FEV1 over 30 minutes. Also recorded were heart rate, time required to use each device, and patient acceptance of each device. There was a large bronchodilator response with albuterol with each of the devices, but there was no difference in the promptness or the magnitude of the bronchodilator response among the three devices. There was a small but statistically significant increase in heart rate which did not differ among devices. Subject ratings of acceptability were MDI alone best, followed by OptiHaler, then AeroChamber. We conclude (1) the bronchodilator response obtained with use of the MDI alone, the AeroChamber and OptiHaler were not significantly different; (2) patients, as a group, found the MDI required less time to use and they favored it over either spacer; (3) while in subjects employing good MDI technique, the addition of either an AeroChamber or an OptiHaler did not improve bronchodilator response. Spacers may have a role in those with poor inhaler technique or in conjunction with inhaled corticosteroids.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Eighteen subjects with moderate asthma participated in this double-blind study comparing the bronchodilator response to albuterol or placebo used in conjunction with three inhalation devices; the metered dose inhaler (MDI) actuator alone, the AeroChamber, and the OptiHaler. The principal comparison was the increase in FEV1 over 30 minutes. Also recorded were heart rate, time required to use each device, and patient acceptance of each device. There was a large bronchodilator response with albuterol with each of the devices, but there was no difference in the promptness or the magnitude of the bronchodilator response among the three devices. There was a small but statistically significant increase in heart rate which did not differ among devices. Subject ratings of acceptability were MDI alone best, followed by OptiHaler, then AeroChamber. We conclude (1) the bronchodilator response obtained with use of the MDI alone, the AeroChamber and OptiHaler were not significantly different; (2) patients, as a group, found the MDI required less time to use and they favored it over either spacer; (3) while in subjects employing good MDI technique, the addition of either an AeroChamber or an OptiHaler did not improve bronchodilator response. Spacers may have a role in those with poor inhaler technique or in conjunction with inhaled corticosteroids.

Key concepts: Bronchodilator, Metered-dose inhaler, Medicine, Inhaler, Asthma, Anesthesia, Inhalation, Bronchodilator Agents

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the bronchodilator response to albuterol administered by the OptiHaler, the AeroChamber, or by metered dose inhaler alone. — Research Paper | ScholarLens