1994PubMedRequires access

[Detection of patent foramen ovale by transcranial Doppler ultrasonography].

Hubert Kwieciński, J Mieszkowski, Adam Torbicki, Jarosław Pniewski, Piotr Pruszczyk

Open publisher page 2 citations

Abstract

This study compares the value of transcranial Doppler ultrasound (TCD) and transesophageal echocardiography (TEE) for detecting a patent foramen ovale (PFO). A total of 61 stroke patients under 65 years of age, were studied. A PFO was detected by TEE in 27 of 61 patients and these results were used as the gold standard. TCD confirmed the presence of PFO in 23 of the 27 patients and detected a PFO in a further 5 patients with normal TEE results. TCD had a sensitivity of 85% (23 of 27) and accuracy of 85% (52 of 61). The prevalence of PFO detected by both methods was 38%.

About this research paper

What this paper is about

This study compares the value of transcranial Doppler ultrasound (TCD) and transesophageal echocardiography (TEE) for detecting a patent foramen ovale (PFO). A total of 61 stroke patients under 65 years of age, were studied. A PFO was detected by TEE in 27 of 61 patients and these results were used as the gold standard. TCD confirmed the presence of PFO in 23 of the 27 patients and detected a PFO in a further 5 patients with normal TEE results. TCD had a sensitivity of 85% (23 of 27) and accuracy of 85% (52 of 61). The prevalence of PFO detected by both methods was 38%.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study compares the value of transcranial Doppler ultrasound (TCD) and transesophageal echocardiography (TEE) for detecting a patent foramen ovale (PFO). A total of 61 stroke patients under 65 years of age, were studied. A PFO was detected by TEE in 27 of 61 patients and these results were used as the gold standard. TCD confirmed the presence of PFO in 23 of the 27 patients and detected a PFO in a further 5 patients with normal TEE results. TCD had a sensitivity of 85% (23 of 27) and accuracy of 85% (52 of 61). The prevalence of PFO detected by both methods was 38%.

Key concepts: Medicine, Patent foramen ovale, Transcranial Doppler, Foramen ovale (heart), Gold standard (test), Radiology, Stroke (engine), Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Detection of patent foramen ovale by transcranial Doppler ultrasonography]. — Research Paper | ScholarLens