2014•PubMedRequires access

[Dissolution testing combined with computer simulation technology to evaluate the bioequivalence of domestic amoxicillin capsule].

Rui-Xue Pan, Yuan Gao, Wan-Li Chen, Yulan Li, Chang-qin Hu

Open publisher page 3 citations

Abstract

Re-evaluation of bioequivalence of generic drugs is one of the key research focus currently. As a means to ensure consistency of the therapeutic effectiveness of drug products, clinical bioequivalence has been widely accepted as a gold standard test. In vitro dissolution testing based on the theory of the BCS is the best alternative to in vivo bioequivalence study. In this article, the conventional dissolution method and flow-through cell method were used to investigate the dissolution profiles of domestic amoxicillin capsules in different dissolution media, and the absorption behavior of the drugs with different release rates (t85% = 15-180 min) in the gastrointestinal tract was predicted by Gastro Plus. The flow-through cell method was thought better to reflect the release characteristics in vivo, and amoxicillin capsules with regard to the release rates up to 45 min (t85% = 45 min) were having a satisfied bioequivalence with the oral solution according to the C(max) and AUC. Although two different dissolution profiles of domestic amoxicillin capsules were found by flow-through cell methods, prediction results revealed that domestic capsules were probably bioequivalent to each other.

About this research paper

What this paper is about

Re-evaluation of bioequivalence of generic drugs is one of the key research focus currently. As a means to ensure consistency of the therapeutic effectiveness of drug products, clinical bioequivalence has been widely accepted as a gold standard test. In vitro dissolution testing based on the theory of the BCS is the best alternative to in vivo bioequivalence study. In this article, the conventional dissolution method and flow-through cell method were used to investigate the dissolution profiles of domestic amoxicillin capsules in different dissolution media, and the absorption behavior of the drugs with different release rates (t85% = 15-180 min) in the gastrointestinal tract was predicted by Gastro Plus. The flow-through cell method was thought better to reflect the release characteristics in vivo, and amoxicillin capsules with regard to the release rates up to 45 min (t85% = 45 min) were having a satisfied bioequivalence with the oral solution according to the C(max) and AUC. Although two different dissolution profiles of domestic amoxicillin capsules were found by flow-through cell methods, prediction results revealed that domestic capsules were probably bioequivalent to each other.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Re-evaluation of bioequivalence of generic drugs is one of the key research focus currently. As a means to ensure consistency of the therapeutic effectiveness of drug products, clinical bioequivalence has been widely accepted as a gold standard test. In vitro dissolution testing based on the theory of the BCS is the best alternative to in vivo bioequivalence study. In this article, the conventional dissolution method and flow-through cell method were used to investigate the dissolution profiles of domestic amoxicillin capsules in different dissolution media, and the absorption behavior of the drugs with different release rates (t85% = 15-180 min) in the gastrointestinal tract was predicted by Gastro Plus. The flow-through cell method was thought better to reflect the release characteristics in vivo, and amoxicillin capsules with regard to the release rates up to 45 min (t85% = 45 min) were having a satisfied bioequivalence with the oral solution according to the C(max) and AUC. Although two different dissolution profiles of domestic amoxicillin capsules were found by flow-through cell methods, prediction results revealed that domestic capsules were probably bioequivalent to each other.

Key concepts: Bioequivalence, Dissolution, Dissolution testing, Amoxicillin, Pharmacology, Bioavailability, Capsule, Dosage form

Related papers

Back to paper searchBrowse research topicsOriginal source
[Dissolution testing combined with computer simulation technology to evaluate the bioequivalence of domestic amoxicillin capsule]. — Research Paper | ScholarLens